8.5 Message List
112
Commands specific to RS-232C or GP-IB are identified by
or
, respec-
tively.
8.5 Message List
• Any spelling mistake in a message results in a command error.
• < >: contents of the data portion.
[Numeric data values are indicated by format as
(NR1)
,
(NR2)
and
(NR3)
, rep-
resenting integer, fixed-point and floating point decimal data values respec-
tively, or as (NRf), representing any of these formats]
• [ ]: optional
Standard Commands
Command
Data Formats (Response
data if a Query)
Description
Error
Ref
page
IDN?
<Manufacturer's name>,
<Model name>,0,
<Software version>
Queries the device ID
*2
RST
Initializes the device
*1
TST?
0 to 3
(NR1)
Initiates a self-test and queries the result
*2
OPC
Requests an SRQ after execution completion
*1
OPC?
1
Queries execution completion
*2
WAI
Waits for operations to finish
*1
CLS
Clears the Event Registers and the Status Byte
Register
*1
ESE
0 to 255
(NR1)
Sets the contents of the Standard Event Status
Enable Register
*3
ESE?
0 to 255
(NR1)
Queries the Standard Event Status Enable
Register
*2
ESR?
0 to 255
(NR1)
Queries and clear the Standard Event Status
Register
*2
SRE
0 to 255
(NR1)
Sets the Service Request Enable Register
*3
SRE?
0 to 255
(NR1)
Queries the contents of the Service Request
Enable Register
*2
STB?
0 to 255
(NR1)
Queries the Status Byte Register
*2
TRG
Requests a sampling
*1
Error description (an error occurs when executing messages in the following cases):
*1 Command Error .........When data is present after the command
*2
Query Error................When the response message exceeds 64 bytes
*3
Execution Error..........When invalid character or numeric data is present
HIOKI BT3564A961-02
Содержание BT3564
Страница 2: ...HIOKI BT3564A961 02...
Страница 44: ...3 7 Displaying Measurement Results 38 HIOKI BT3564A961 02...
Страница 80: ...4 12 Reset Function 74 HIOKI BT3564A961 02...
Страница 89: ...5 4 Internal Circuitry 83 5 Chapter 5 External Control EXT I O 5 4 Internal Circuitry HIOKI BT3564A961 02...
Страница 98: ...6 3 Printing 92 HIOKI BT3564A961 02...
Страница 170: ...8 8 Sample Programs 164 HIOKI BT3564A961 02...
Страница 182: ...10 3 Error Indication 176 HIOKI BT3564A961 02...
Страница 202: ...Appendix 11 Dimensional Diagram A20 HIOKI BT3564A961 02...
Страница 206: ...Index 4 HIOKI BT3564A961 02...
Страница 207: ...HIOKI BT3564A961 02...
Страница 208: ...HIOKI BT3564A961 02...
Страница 209: ...HIOKI BT3564A961 02...
Страница 210: ...HIOKI BT3564A961 02...