2.2  Installing and Uninstalling the Software

HIOKI

Installation

Use the following procedure to install the software.

1.

Set up the computer.
Shut down all currently running applications.

2.

Insert the supplied CD disc into the CD-ROM drive.

3.

Double-click the setup file (setup.exe) on the CD.

Supposing the drive letter for the CD-ROM drive is R (if another letter,
substitute before the colon) then in the Windows 

Start

 menu, select

Run

, and enter 

R:\english\setup.exe

, then click OK.

4.

The 9625 installer start: follow the directions on the screen to
complete the installation.

Uninstallation

Use the following procedure to uninstall the software.

1.

In the Windows 

Start 

menu, select 

Settings

, and 

Control Panel

2.

Click the 

Add/Remove

 Programs icon, to display the 

Add/

Remove Programs Properties

 dialog.

3.

In the 

Install/Uninstall

 tab of the dialog, click on 

9625 POWER

MEASUREMENT SUPPORT SOFTWARE

 in the list of applications,

and click 

Add/Remove

.

This runs the uninstaller, which removes the 9625 software.

2.2 Installing and Uninstalling the Software

• When installing, if other application are running it may not be possible to

complete the installation. As far as possible, close all other applications
before beginning the installation. In particular, if any anti-virus software is
running, it may prevent the installation, even though it is not a virus. In
this case, make the appropriate settings in the anti-virus software to allow
the installation to proceed.

• Following installation, the computer may need to be restarted.

Содержание 9625

Страница 1: ...POWER MEASUREMENT INSTRUCTION MANUAL 9625 SUPPORT SOFTWARE...

Страница 2: ......

Страница 3: ...equirements 9 2 2 Installing and Uninstalling the Software 10 2 3 Launching and Exiting the 9625 11 2 4 Loading Saving Data 12 2 4 1 Loading a Measurement data File 12 2 4 2 Loading a Combined File 15...

Страница 4: ..._43 7 1 Basic Operation 44 7 2 Advanced Operation 46 Chapter 8 Displaying a Harmonic Graph ________47 8 1 Basic Operation 48 8 2 Advanced Operation 51 Chapter 9 Displaying a Waveform of Harmonic Measu...

Страница 5: ...system 2 Explanation of other rights and restrictions 1 Restrictions on reverse engineering decompiling and disassembling You may not reverse engineer decompile or disassemble the software 2 Separati...

Страница 6: ...vised software 2 If the software does not operate in accordance with the supplied Instruction Manual or the software media or Instruction Manual are damaged in any way you have one year from the date...

Страница 7: ...sentative Instruction manual CD Symbols The following symbols in this manual indicate the relative importance of cautions and warnings Notation Unless otherwise specified Windows represents Windows 20...

Страница 8: ...n Do not use a ball point pen or hard tipped pen because there is a danger of scratching the surface and corrupting the data Do not use adhesive labels Do not expose the disc directly to the sun s ray...

Страница 9: ...ne on top of another 2 Summary Display Displays a list of measurement data 3 Daily Weekly and Monthly Report Display Displays a daily weekly or monthly report of demand measurements 4 Harmonic Analysi...

Страница 10: ...ntaneous value and integrated value Demand measurement data file CSV format with extension DEM Instantaneous value maximum value minimum value and demand value Harmonic measurement data file CSV forma...

Страница 11: ...lection Line graph bar graph 2 axis graph and 3 dimensional graph Line style color setting Line style and line color are selectable separately for each piece of data Marker display is available Stacke...

Страница 12: ...ay Prints the data shown by the time series graphic display and dis plays the preview Summary display Prints the data shown by the summary display and displays the pre view Harmonic display Prints the...

Страница 13: ...day for a daily report seven days for a weekly report and one month for a monthly report The facility capacity is set in the Load data file dialog Click File on the menu bar and then select Load file...

Страница 14: ...8 1 3 Calculation Formulas HIOKI...

Страница 15: ...MB or more recomended Hard Disk Free disk space of 128 MB or more Display XGA 1024 x 768 or higher Disk System CD ROM drive Used only for installation Printer Required for report printing on the compu...

Страница 16: ...ws Start menu select Settings and Control Panel 2 Click the Add Remove Programs icon to display the Add Remove Programs Properties dialog 3 In the Install Uninstall tab of the dialog click on 9625 POW...

Страница 17: ...POWER MEASUREMENT SUPPORT SOFTWARE 2 The main screen entitled HIOKI 9625 POWER MEASUREMENT SUPPORT SOFTWARE appears Exiting _______________________________________________________ 1 Select File Exit f...

Страница 18: ...ension BIN 1 Click the Load data file button or select File Load file on the menu bar 2 The Load data file dialog will appear 2 4 Loading Saving Data If a waveform data file or a short term interval d...

Страница 19: ...the calculation of the demand factor for a daily weekly or monthly report The default setting is 0 kW Change the setting as necessary 1 Select a data file for which the setting can be changed 2 Click...

Страница 20: ...he waveform data file 69WAVEXX WUI When multiple data files are loaded the measurement periods of all files must not exceed one year When a data file is large in size an extended period may be require...

Страница 21: ...ed 9625 combined file Extension DAT 1 Click the Open combined file button or select File Open Combined file on the menu bar 2 The Open dialog will appear 3 Select a combined file to be loaded and clic...

Страница 22: ...ile and save the file as a new combined file 1 Select File Save the combined file as on the menu bar 2 The Save As dialog will appear 3 Enter a filename and click 2 4 4 Saving a Combined File Save cha...

Страница 23: ...ow Load the file that was worked on last this becomes effective after the next startup Return to the default settings this is effective at the next startup only Select Settings Options Others on the m...

Страница 24: ...18 2 4 Loading Saving Data HIOKI...

Страница 25: ...6 Displaying the Daily Weekly or Monthly Report page 37 4 Harmonic List Screen Displays a list of harmonic measurement data Chapter 7 Displaying a Harmonic List page 43 5 Harmonic Graphic Screen Displ...

Страница 26: ...IOKI When data has been loaded the time series graph will be shown 3 2 Screen Configuration Menu bar Tool bar Status bar Displays the time during cursor measurement explanations of the menu bar or too...

Страница 27: ...pened Com bined File Display a list of the combined files worked on last Exit Exit the 9625 Edit Copy Copy the currently displayed screen to the clipboard View Toolbars Show or hide the toolbar Change...

Страница 28: ...combined file 4 Save as CSV file 5 Copy 6 Print preview 7 Print The currently displayed screen can be pasted to the clipboard and worked on using another program such as a word processing pro gram Cl...

Страница 29: ...Vertical axis Vertical axis Cursor Cursor Vertical axis Vertical axis Cursor Graph type selection Cursor indicated time Data interval setting Display period Display range selection Display data item s...

Страница 30: ...raph Check the box of each item to be displayed Select Display Item Left click on the parameter of an item and a list of selectable parame ters will appear Select an item to display from the list Sele...

Страница 31: ...the data name of an item and a list of selectable data names will appear Select the name of the data to be displayed Change Graph Format Left click on the graph of an item and the Change graph format...

Страница 32: ...Set Display Name Set the name of each display item to be used in printout Left click on the display name of an item and the Display name dialog will appear Check the Create setting manually box to set...

Страница 33: ...diately before the displayed time of each interval will be dis played as made at the actual time 5 Move Display Range The display period may be changed by moving the scroll bar 6 Set Display Period Th...

Страница 34: ...lly set automatically but can be changed manually The upper limit and lower limit of the vertical axis are also changed using the sliders Set Grid Show or hide the grid line Set the color and line sty...

Страница 35: ...using the setting for the measurement data regard less of this setting 3 Change Background Color The background color of the graph display area can be changed Select Settings Options Others on the me...

Страница 36: ...time scale of a millisecond will not be shown when short term interval all wave data is displayed at the data interval of all wave 6 Display 3D Graph Time series graphs may be displayed in three dime...

Страница 37: ...ted data Click the summary tab to display Displaying Summary Chapter 5 Screen Data interval Display period Display range setting scrolling setting scrolling Detail item selection Display start stop ti...

Страница 38: ...um will appear Select a data type from the list Select Circuit No Left click on the circuit of an item and a list of selectable circuit num bers will appear Select the circuit No of the data to be dis...

Страница 39: ...er than the interval of the loaded data cannot be set When multiple pieces of data have been loaded a larger interval will be used If the data interval is set to other than an integral multiple of the...

Страница 40: ...5 Set Display Period The display period may be changed by moving the scroll bar NOTE Any changes in settings 2 to 5 above will be reflected in the settings for the time series graph screen 6 Scroll Sc...

Страница 41: ...in the vertical axis set tings of graph When the Display CSV format data by the number of digits in default setting box is checked numerical data in the CSV for mat will be shown with the number of de...

Страница 42: ...lect Settings Options Others on the menu bar Set if necessary Changes in this setting will be reflected in the time scale for the time series graphic display and daily weekly monthly report display NO...

Страница 43: ...the sum of measurements taken at intervals of one day for a week The monthly report shows numerically the sum of measurements taken at intervals of one day for a month Click the Report Daily Weekly Mo...

Страница 44: ...ct an item to display from the list Select Circuit No Left click on the circuit of an item and a list of selectable circuit num bers will appear Select the circuit No of the data to be displayed Selec...

Страница 45: ...mand Period Select a demand period for the data to be displayed at either 30 minutes or 1 hour NOTE An interval smaller than the measurement interval of the loaded data cannot be set 3 Set Display Tim...

Страница 46: ...of decimals When the Display CSV format data by the number of digits in default setting box is checked cursor measurement values will be displayed using the setting for the measurement data regard le...

Страница 47: ...mmary display 4 Sum Up Data The total and average of demand values active power maximum demand time of maximum demand load factor and demand factor will appear at the bottom of the data list When mult...

Страница 48: ...check the Display the integrated power in each time division box 6 Display with CO2 Conversion Integrated active power kWh values can be converted for display as CO2 carbon dioxide exhaust values Sel...

Страница 49: ...monic content and phase angle are also displayed A harmonic list cannot be displayed when the loaded data does not contain harmonic data Click the Harmonic List tab to display Displaying a Harmonic Li...

Страница 50: ...he value of an item and a list of selectable data types instantaneous average maximum and minimum will appear Select a data type from the list Select Circuit No Left click on the circuit of an item an...

Страница 51: ...item and the Display name dialog will appear Check the Create setting manually box to set the display name of each item separately To use a common display format choose symbols in the list to enter th...

Страница 52: ...display unit for the vertical axis and measurement value and the num ber of decimals When the Display CSV format data by the number of digits in default setting box is checked cursor measurement valu...

Страница 53: ...onic power phase angle A harmonic graph cannot be displayed when the loaded data does not contain harmonic data Click the Harmonic Graph tab to display Displaying a Harmonic GraphChapter 8 Linear axis...

Страница 54: ...the value of an item and a list of selectable data types instantaneous average maximum and minimum will appear Select a data type from the list Select Circuit No Left click on the circuit of an item a...

Страница 55: ...d in printout Left click on the display name of an item and the Display name dialog will appear Check the Create setting manually box to set the display name of each item separately To use a common di...

Страница 56: ...evel or harmonic content is displayed the linear axis or logarithmic axis can be chosen as the vertical axis 5 Measure with Cursor Left click in the graph display area and the cursor will appear The m...

Страница 57: ...ertical axis setting dialog Set Vertical Axis The vertical axis is normally set automatically but can be changed manually in the case of a linear axis Set Grid Show or hide the grid line Set the color...

Страница 58: ...s and measurement value and the num ber of decimals When the Display CSV format data by the number of digits in default setting box is checked cursor measurement values will be displayed using the set...

Страница 59: ...isplayed if the loaded data does not contain waveform data Click the Weveform tab to display Displaying a Waveform of Chapter 9 Harmonic Measurement Data Legend of line Display data selection Waveform...

Страница 60: ...ck in the waveform display area and the cursor will appear The measurement of the point at which the cursor is located will be dis played To move the cursor left click at the point to which the cursor...

Страница 61: ...dis play the Vertical axis setting dialog Set Vertical Axis The vertical axis is normally set automatically but can be changed manually Set Grid Show or hide the grid line Set the color and line styl...

Страница 62: ...bar Set the display unit for the vertical axis and measurement value and the num ber of decimals When the Display CSV format data by the number of digits in default setting box is checked cursor measu...

Страница 63: ...57 HIOKI Display the settings of measurement data Click the Setting tab to display Displaying Settings Chapter 10 Measurement data selection Tab...

Страница 64: ...yed from the loaded data files 2 Set Column Width Place the cursor on the right edge of the column to be adjusted the cursor will change to a cross Double click to adjust the column width automaticall...

Страница 65: ...o create reports using commonly avail able computer spreadsheet programs 1 Select Screen Display the screen from which to save data in CSV format 2 Save in CSV format Click the Save as CSV file button...

Страница 66: ...60 HIOKI...

Страница 67: ...rmonic list graph waveform screen and set ting screen on the printer connected to the PC 1 Select Screen Display the screen to be printed 2 Enter Printing Header You can add a logo title comments to t...

Страница 68: ...he menu bar The Printer Settings dialog will appear Either color or monochrome printing can be selected To print in mono chrome check the B W PRINT box 4 Display Print Preview Click the Print preview...

Страница 69: ...ck the Print button or select File Print on the menu bar The Print dialog will appear After confirming printer settings click to start printing NOTE Some colors selected on the screen might not be pri...

Страница 70: ...64 HIOKI...

Страница 71: ...81 268 28 0568 E mail os com hioki co jp URL http www hioki co jp Printed in Japan 9625A981 01 All reasonable care has been taken in the production of this manual but if you find any points which are...

Страница 72: ...2 Japan TEL 81 268 28 0562 FAX 81 268 28 0568 E mail os com hioki co jp URL http www hioki co jp HIOKI USA CORPORATION 6 Corporate Drive Cranbury NJ 08512 USA TEL 1 609 409 9109 FAX 1 609 409 9108 962...