11.3 Saving Data
282
Save waveforms automatically during measurement. Set auto save before
beginning measurement. Waveforms can be saved in binary or text format.
The channels of all sheets for which waveform display is set to [On] are saved.
11.3.7 Automatically Saving Waveforms
When using auto save during measurement, do not remove the storage media
specified as the save destination until the measurement operation is completely
finished. Data on the storage media may be damaged.
If the file size would exceed 2 GB, save using Divided Save or Thinning Save
(text format only).
See
"Appendix 2.2 Waveform File Sizes" (p. A22)
2
3
4
5
Automatically Saving Waveforms
To open the screen: Press the
SET
key
Select
with the
SUB MENU
keys
Save Settings screen
See
Screen Layout (p. 40)
Operating Key
Procedure
1
Set auto save (p. 276).
Set the save destination.
2
Enable the saving of waveforms.
CURSOR
Move the cursor to the
[Waveform]
item.
F2
Select
[On]
(default setting)
.
3
Enter a save name (if you want to use a different name).
CURSOR
Move the cursor to the
[Name]
item.
F1 to F8
Enter the save name (Default setting: AUTO).
See
"Entering Text and Comments" (p. 66)
4
Select the contents (Name Pattern) to be automatically
added to the save name
CURSOR
Move the cursor to the
[Name Pattern]
item.
F1 to F8
Select the contents to be automatically added to
the save name
5
Set the save format.
CURSOR
Move the cursor to the
[Format]
item.
F1 to F8
Select the save format.
Numbering
Appends serial numbers beginning
with 0001 as a suffix to the save name.
Trig (suffix)
Appends the trigger date and time as a
suffix to the save name.
Trig (prefix)
Appends the trigger date and time as a
prefix to the save name.(default set-
ting)
Binary
Select this format if waveforms are to be re-
loaded on the instrument.
Text
Select this format if waveforms are to be
read on a PC.
"11.6.1 Example of Saving Data" (p. 298)
(Proceed to the next step.)
[Auto Save] Page
Save Name
Up to 40 characters (single byte and dou-
ble byte) can be used for the save name.
"File Names" (p. 270)
If the data is saved in text format
,
it cannot be reloaded on the instrument.
When a file is saved in text format, some
characters may differ from those used on
the instrument. (p. 298)
When saving a file in text format, note that
a PC will not be able to handle the follow-
ing characters if they are used.
• ASCII:
+ = [ ] \ / | : * ? “ < > ; ,
• White space characters
Содержание 8860-50
Страница 2: ......
Страница 12: ...Contents x...
Страница 18: ...Reading this Manual 6...
Страница 24: ...1 3 Interconnection and Block Diagrams 12...
Страница 180: ...6 12 Making Trigger Settings on the Waveform Screen 168...
Страница 246: ...8 15 Inserting and Searching for Event Marks on a Waveform 234...
Страница 354: ...12 7 Print Examples 342 Print Example 4 Row Printing 1 4 steps Settings data Each step is 25 div...
Страница 356: ...12 7 Print Examples 344 A B Waveform_________________________________________________...
Страница 360: ...12 7 Print Examples 348 Event ________________________________________________________ Event mark...
Страница 406: ...14 2 External I O 394...
Страница 489: ......
Страница 490: ......