4.3 Acquiring Waveforms Using the Utility Functions
111
4
Chapte
r 4
Me
asuremen
t Co
nfiguration Sett
ings
2
3
1
Memory Division: Display Settings
To open the screen: Press the
SET
key
Select
with
the
SUB MENU
keys
Mem Div Settings screen
See
Screen Layout (p. 37), To set from the Waveform screen
Operating Key
Procedure
1
To display any block on the Waveform screen
Set the display blocks
(This can also be set on the Waveform screen.(p. 220))
CURSOR
Move the cursor to the
[Display Block].
F1 to F8
Set the number of blocks to display on the Wave-
form screen after measurement.
2
To display multiple blocks as overlaid waveforms
Enable the Reference Block function
CURSOR
Move the cursor to the
[Ref Block].
F2
Select
[On]
.
(When Reference Blocks are enabled [On])
Select whether to reference every block
CURSOR
Move the cursor to the row number of the Refer-
ence Block to select its block number.
F7
or
F8
Enables (On) or disabled (Off) Reference Blocks.
When enabled, the frame of the selected block is
red.
F1 to F8
To overlay all waveforms, select the [All On] but-
ton.
3
To display every block as its waveform is acquired
Enable the Trace Waveform display
CURSOR
Move the cursor to the
[Wave Display].
F2
Select
[On]
.
Viewing Memory Division waveforms on the Waveform screen
See
"8.12 Viewing Waveforms in Every Display Block (Memory Division)"
(p. 220)
Off
Reference Blocks are not displayed
(default setting)
On
Reference Blocks overlay Display blocks
on the display.
All Off
Disables all block references.
All On
Enables all block references.
Off
The waveform of the specified Display
Block is displayed after recording the
specified number of Used Blocks.
(default setting)
On
Waveforms are displayed one block at a
time as they are acquired at each trigger
event.
Display Block (Green)
Reference Block (Red)
Measurement data is recorded at the
colored positions.
When the Display Block is 5 and the
Reference Block is 3
Reference Block No.
Enabling the Trace Waveform display
lengthens dead time.
About Dead Time:
See: "Difference Between Dead Times
During Normal and Memory Division
Recording" (p. 112)
When Using Auto Save
When disabled, displayed images are not
saved.
Even if the Roll Mode is enabled (other
than Off), it is not usable when the Trace
Waveform display is disabled.
Reference Block Selection
Reference Blocks can also be selected
and deselected in the [Reference Block]
item on the [List] display.
Содержание 8860-50
Страница 2: ......
Страница 12: ...Contents x...
Страница 18: ...Reading this Manual 6...
Страница 24: ...1 3 Interconnection and Block Diagrams 12...
Страница 180: ...6 12 Making Trigger Settings on the Waveform Screen 168...
Страница 246: ...8 15 Inserting and Searching for Event Marks on a Waveform 234...
Страница 354: ...12 7 Print Examples 342 Print Example 4 Row Printing 1 4 steps Settings data Each step is 25 div...
Страница 356: ...12 7 Print Examples 344 A B Waveform_________________________________________________...
Страница 360: ...12 7 Print Examples 348 Event ________________________________________________________ Event mark...
Страница 406: ...14 2 External I O 394...
Страница 489: ......
Страница 490: ......