5. Release the two screws on the switch unit, so that the two conductors can be pulled out of the switch
unit.
Depending on the version, the switch unit has a capacitor connected.
6. Remove the supply cord.
7. Push the new supply cord through the protective sleeve.
8. Insert the ends of the flexible conductors in the switch unit and tighten both screws on the switch unit.
➥ Both flexible conductors should be firmly secured in the switch unit.
9. Place the supply cord in the clamp.
10. Fit the upper part of the clamp over the supply cord and tighten the clamp screws.
Technical data
Torque (Clamp)
1.35 Nm … 1.75 Nm
(1.00 ftlb
f
… 1.29 ftlb
f
)
Take care to ensure that the insulation on the supply cord still extends 5 mm beyond the clamp.
11. Fit the protective sleeve into the retaining groove provided in the casing.
12. Place the casing in position and insert and tighten the casing screws.
Technical data
Torque (Casing)
1.35 Nm … 1.75 Nm
(1.00 ftlb
f
… 1.29 ftlb
f
)
7.3
Replacing the carbon brushes
DANGER
Risk of injury!
Risk of electric shock.
▶
The power tool may be operated, serviced and repaired only by trained, authorized personnel. This
personnel must be specially informed of any possible hazards.