page 1
February 2014
Product Data Sheet
HIT-HY 200
with HIT-Z
Basic loading data (for a single anchor)
All data in this section applies to
■
Correct setting (See setting instruction)
■
No edge distance and spacing influence
■
Steel failure
■
Base material thickness, as specified in the table
■
Embedment depth, as specified in the table
■
One anchor material, as specified in the tables
■
Non cracked concrete f
c,cyl
= 32 MPa
■
Temperate range I (min. base material temperature -40°C, max.
long term/short term base material temperature: +24°C/40°C)
■
Installation temperature range -10°C to +40°C
Embedment depth and base material thickness for the basic loading data
Recommended loads
Anchor size
M8
M10
M12
M16
M20
Typical embedment depth h
ef
[mm]
80
90
110
145
180
Base material thickness h [mm]
140
150
170
245
280
Recommended loads
Anchor HIT-Z
Anchor size
M8
M10
M12
M16
M20
Tensile N
rec
[kN]
11.4
18.1
25.9
45.7
69.5
Shear V
rec
[kN]
6.9
10.9
15.4
27.4
41.7
Note: For varied embedment depths please contact your local Hilti engineer for further details.
Hilti HIT-HY 200 with HIT-Z
Injection Mortar System
Benefits
■
no cleaning required: zero
succeptability to borehole cleaning
conditions with dry and water
saturated concrete base material
■
maximum load performance in
cracked concrete and uncracked
concrete
■
suitable for cracked and non-cracked
concrete C 20/25 to C 50/60
■
suitable for use with diamond cored
holes in non-cracked or cracked
concrete with no load reductions
Hilti HIT-HY 200-R
500 ml foil pack
(also available as 330 ml
foil pack)
Static mixer
HIT-Z
HIT-Z-R rod
CE
conformity
European
Technical
Approval
Concrete
A4
316
Corrosion
resistance
Tensile
zone
PROFIS
anchor design
software
No cleaning
required for
approved
loads
Seismic
Diamond
drilled
holes