5.4 Position of holes drilled for fastening the rail supports
@
Distance between anchors with
track support positioned on the
inside = 9.3 in (235 mm)
;
Distance between anchors with
track support positioned on the
outside = 9.1 in (230 mm)
=
Distance between track supports
with support positioned on the
inside = 5.7 in (144 mm)
%
Distance between track supports
with support positioned on the
outside = 5.5 in (139 mm)
&
Distance between anchors for
flush-cutting = 10.8 in (274 mm)
(
Distance between track supports
for flush-cutting = 7.2 in (183 mm)
▶
The holes drilled for fastening the rail supports should be positioned as shown in the
above illustration.
5.5 Power source
WARNING
Risk of electric shock!
Severe injury and burns can result if any attempt is made to
operate the tool without an earth/ground conductor and ground fault circuit interrupter
correctly connected.
▶
Irrespective of whether mains power or generator power is used, always make sure
that an earth/ground conductor and ground fault circuit interrupter are present in the
power supply and that these are correctly connected.
▶
Do not use the product unless these safety measures are in place and fully operational.
Fuse rating
Make sure that the electric supply installation on the jobsite (3 x 480 ... V) has the
following fuse rating:
Technical data
Mains fuse rating
16 A
Ground fault circuit interrupter (GFCI)
Type A, 30 mA