Commissioning
49/90
7.5
Autonomous operating mode, capturing on USB memory
device
7.5.1
Full capturing process (Live-Dump-Mode)
Proceed as follows if you want to use the analyzer device NANL-B500G-RE
in the Autonomous operating mode
in Live dump mode
with an USB
memroy device and want to record data during the entire time span of an
analysis process:
Step 1: Safety precautions
Device Destruction
Ø
The voltage applied at the NANL-B500G-RE device must not exceed 30
V, otherwise the device may be destroyed.
Ø
At the I/O signal pins of the external IO interface use exclusively 3.3 V
or 24 V signaling voltage. Higher signaling voltages lead to severe
damage to the NANL-B500G-RE device!
Step 2: Connect the device to USB, use the autonomous operating
mode
in "live dump mode"
and transfer evaluation data to a PC
Ø
Connect the analyzer device NANL-B500G-RE to an
external 24V
power supply
.
Ø
Connect the USB memory device (USB stick or USB hard disk with at
least 100 MByte capacity) to the USB socket on the reverse side of the
NANL-B500G-RE analyzer device.
Ø
When using an USB device with a power consumption of more than 500
mA, connect a separate power supply; If required, it is also possible to
feed it via an USB hub.
Ê
The analyzer device NANL-B500G-RE displays the autonomous
operating mode (live dump mode) as a particular LED state (STA0-LED/
orange/On, refer to section
SYS, STA0, STA1, I/O, LINK and RX (Front
page 75]).
Ø
To start capturing, briefly press the red REC button on the front side of
the device.
Note:
If when switching on the analyzer device NANL-B500G-RE an USB
memory device with a partition marked as "bootable" is connected
to the analyzer device NANL-B500G-RE, the netANALYZER device
may not start correctly (SYS LED is yellow).
Ê
The analyzer device NANL-B500G-RE starts capturing the data traffic
in .pcap files, which are stored in the root directory of the USB memory
device.
Ø
To stop capturing, press the red REC button on the front side of the
device for at least 1 second.
netANALYZER device NANL-B500G-RE | Installation, operation and hardware description
DOC091110UM26EN | Revision 26 | English | 2019-07 | Released | Public
© Hilscher 2007-2019