Commissioning
83/146
9.2.1
Configuring the IO-Link Wireless Master
Ø
Select
IO-Link Wireless
Master
in the left column of the netFIELD
Wireless Web Server.
Ø
On the
Channel selection
tab select the WLAN channels required (for
example, WLAN channels 01 to 04).
Ø
Then open the
Configuration
tab.
Figure 38: IO-Link Wireless Master > Configuration tab
Ø
Use the following IO-Link Wireless Master settings as possible values
for commissioning. They will allow you to put the NFD-3090-PNS-IOLM
\W device into operation.
Parameter
Possible value for commissioning
Note
Master ID
1
Enter the Master ID this way: “1”
Pairing Timeout
5
seconds
Advanced Connectivity
(intended for future use)
-
WT1 Track Mode
Cyclic
WT2 Track Mode
Cyclic
WT3 Track Mode
Cyclic
WT1 TXPower
31
“31” = max. transmission power
WT2 TXPower
31
WT3 TXPower
31
Table 44: Configuration, possible values for IO-Link Wireless Master (example)
Important:
For proper device operation all three tracks must be activated.
Ø
Click
Apply
.
Ê
The request appears
Applying configuration will restart
the device. Are you sure?
.
NFD-3090-PNS-IOLM\W | Hardware, installation and commissioning
DOC201101UM03EN | Revision 3 | English | 2022-02 | Released | Public
© Hilscher 2020 - 2022