Configuration
63/146
8.3.8.2
Port status
Ø
Select the wireless IO-Link port in the left column of the netFIELD
Wireless Web Server.
Ø
Open the
Status
tab.
ð
The current values for the status data of the selected wireless IO-Link
port appear.
Figure 25: Status tab, Port status (example)
Parameter
Description
Value, Value range
Port state
Current port state of wireless IO-Link port
Descriptions of the possible values are listed in table
Pairing success, Pairing timeout, Pairing
wrong slot type, Inactive, Port ready,
Communication ready, Operate,
Communication lost, Revision fault,
Compatibility fault, Serial number fault,
Process data fault, Cycle time fault
Port quality
Status information of process data
Input process data is valid,
Input process data is not valid
Output process data is valid,
Output process data is not valid
PDI valid, PDI invalid,
PDO valid, PDO invalid
Revision ID
Revision ID of the connected device
This parameter is specified by the connected device.
It indicates software revision running on the
connected device.
0: No device connected
Others: Revision ID of connected device
Master cycle time
Cycle time of communication in Operate mode
The Master cycle time is a Master parameter and
sets up the actual cycle time of a particular wireless
IO-Link port.
“Free running”: The Minimum Master cycle time is
configured, based on the PD Segmentation length,
Slot Type and Max Retry configurations.
“Free running”, 5 ms … 315 ms
Input data length
Real input data length of connected device in bytes
0 … 32
Output data length Real output data length of connected device in bytes
0 … 32
Vendor ID
Vendor ID of the connected IO-Link Device
0 … 0xFFFF, Default: 0
Device ID
Device ID of the connected IO-Link Device
0 … 0xFFFFFF, Default: 0
Signal quality
Signal quality gives a relative indication on strength
of radio connection between IO-Link Wireless Master
device and the connected IO-Link Device.
The indicated value does not change during runtime.
0% … 100%
Table 35: Port status, overview
NFD-3090-PNS-IOLM\W | Hardware, installation and commissioning
DOC201101UM03EN | Revision 3 | English | 2022-02 | Released | Public
© Hilscher 2020 - 2022