3.6
Alarm & Warning Table
3.6.1
General Alarms
Id Alarm
Meaning
Solution
AL 1
General
EEPROM failure
Detected an Error in the internal memory of the card. Turn off and on
again. If the error persists, replace the card.
AL 2
General
Key-off failure
Return on the key signal. Turn off the machine, wait at least 2 seconds,
and then turn it on again. If the problem persists, replace the key block.
AL 3
General
Undervoltage
Detected supply voltage less than 15V (even instantly). Check the bat-
teries and their connection and the connection between the batteries and
the main card. If the error persists, replace the card.
AL 4
General
Overvoltage
Detected supply voltage more than 35V (even instantly). Check the bat-
teries and their connection and the connection between the batteries and
the main card. If the error persists, replace the card.
AL 5
General
Battery not connected
Detected no voltage on the battery poles but present on the key input
(disabled for this machine).
AL 6
General
Keyboard
Communication
No communication between display and main board. Check the connec-
tion between the cards. If the problem persists, replace the main card or
the display card.
AL 7
General
Communication FFM
Lack of communication between the BB and the main card. Check the
connection between the cards. If the problem persists, replace the main
card or the BB.
AL 8
General
Communication 1
Internal error in the main card BUS data, turn off and on again. If the
problem persists, replace the main card.
AL 9
General
Communication 2
Internal error in the main card BUS data, turn off and on again. If the
problem persists, replace the main card.
AL 10
General
Insert Tag
One of the enabled TAGs is not inserted. Enter one of the enabled TAGs
in the Slot.
AL 11
General
Invalid Tag
The inserted TAG is not enabled. Enter one of the enabled TAGs in the
Slot.
AL 12
General
Update in
progress. . .
The machine is updating the parameter list. Wait for the end of the oper-
ation.
AL 13
General
Restart
the Machine
After updating the parameters (AL 12) indicates that is necessary to
restart the machine.
AL 14
General
Recovery Full
The recovery tank is full, drain it.
17
Содержание TRIDENT T26SC PLUS
Страница 1: ...SERVICE MANUAL TRIDENT T26SC PLUS Version AB Date November 7 2018 Document Number 10077484...
Страница 4: ...Part I Product Introduction 4...
Страница 8: ...Part II Anomalies Resolution Guide 8...
Страница 28: ...Part III Machine Description 28...
Страница 30: ...5 2 Location of Electrical components 30...