9
ATTENTION!
Be certain to clear the case of any loose
packaging or case materials before ener-
gizing the case. Failure to do so may re-
sult in case damage or malfunction.
ATTENTION!
Be certain that all piping and electrical
connections comply with local codes.
PLUMBING
The drain outlet is specially molded out of PVC material
and is located in the front-center of the case for convenient
access. The “P” trap, furnished with the case, is construct-
ed of schedule 40 PVC pipe (Fig. 11). Be certain that all
connections are water-tight and sealed with the appropri-
ate PVC or ABS cement.
Fig. 11 “P” trap; drain line
The drain lines can be run left or right of the tee, with the
proper pitch to satisfy local drainage requirements. Since
the kickplate is shipped loose with the case, you should
have open access to the drain line area during installation.
If the kickplate has been installed, you will fi nd it easy to
remove. Simply lift the kickplate up from the "J" rail and
pull it out, away from the case (see
Trim Out
section on
pages
).
ELECTRICAL
Electrical hookups are made to a junction box located top-
rear-left of the case (Fig. 12).
For case-to-case wiring, run conduit between the junction
boxes or run wiring through the raceway. For more detailed
electrical wiring information, see
Appendix
%
.
LIGHTING
Lighting for reach-in door cases is pre-installed during the
manufacturing process. The main door frame light switch
is located inside the case on the door frame mullion.
For cases featuring horizontal cornice lighting, a toggle
switch is located on the left hand top flue panel.
For any questions or service needs, please contact our
Case Division Customer Service Department toll-free at
1-800-283-1109.
"P"
"P"
TRAP
TRAP
DRAIN
DRAIN
LINE
LINE
Fig. 12 Junction box
RQWRSRI
case
CASE CONNECTIONS