4
Theory of Operation
The compressor has three stages of compression. Each stage compressing the air to a
higher pressure than previous.
A.
The user activates the compressor with the power switch on the side of the machine and
attaches the compressor to the cylinder.
B.
The user selects the desired units and fill pressure.
C.
The user starts the compressor. The motor is switched on via a relay and pressure builds.
a.
The pressure and temperature are constantly monitored via sensors.
b.
When the temperature goes above 75 degrees Celsius the filling will pause and
restart when 65 degrees Celsius is reached.
c.
Once the desired pressure is released the compressor stops filling.
D.
Air is taken through the inlet filter into stage one.
E.
The air passes into stage 2 and is further compressed.
F.
The air passes through a filter and into stage 3 and is further compressed.
G.
The air is passed into a water separator which removes the majority of moisture from the
air.
H.
The air passes from the compressor into the cylinder
Содержание 3000-001
Страница 2: ...2 Overview...
Страница 10: ...10 4 Remove the middle right bullet valve housing 5 Remove pipe on left hand side of compressor head...
Страница 18: ...18 5 Remove dowel pin with suitable tool...
Страница 19: ...19 6 Slide up piston and inspect stage 2 O ring...
Страница 20: ...20...
Страница 22: ...22 5 Crank case maintenance 1 Remove silicon oil reservoir 2 Remove M4 bolts...
Страница 23: ...23 3 Remove acetal cap 4 Inspect and clean the inside of the crank case...