3
Model Specification
MODEL
CODE
VOLTAGE
Hz
POWER
UK
3000-001
230
50
0.75 kW
US
3000-002
115
60
0.75 kW
EU
3000-003 (004)
230
50
0.75 kW
AUS
3000-005
230
50
0.75 kW
Maintenance Schedule
OPERATION
TIME PERIOD
Change crank oil.
50 hours running time or 1 year's use.
Whichever comes first.
Replace ball valves.
50 hours running time or if compressor
function decreases.
Replace piston O-rings.
When required.
Replace or clean final stage valves.
When pressure release valve hisses
Replace side bullet valves.
50 hours running time or if compressor
function decreases.
Содержание 3000-001
Страница 2: ...2 Overview...
Страница 10: ...10 4 Remove the middle right bullet valve housing 5 Remove pipe on left hand side of compressor head...
Страница 18: ...18 5 Remove dowel pin with suitable tool...
Страница 19: ...19 6 Slide up piston and inspect stage 2 O ring...
Страница 20: ...20...
Страница 22: ...22 5 Crank case maintenance 1 Remove silicon oil reservoir 2 Remove M4 bolts...
Страница 23: ...23 3 Remove acetal cap 4 Inspect and clean the inside of the crank case...