background image

 

Photocell P5200 user manual 

I.

 

Technical Specification

  

1.

 

Working voltage: 12~24VAC/DC   

2.

 

Working current(24VDC):emitter: ≤8mA        receiver: ≤30mA 

3.

 

Photocell wavelength: 940nm 

4.

 

Angle of emission: ≤±5º 

5.

 

Receiving range: ≥12m 

6.

 

Angel adjustment of PCBA: 0

180 º 

7.

 

Working temperature: -20º

+60

 

8.

 

Relay contact loading capacity: 1A/30VDC 

9

Size: 100*40*35mm

 

II.

 

Safety Instruction

 

1.

 

For security, please read the user manual carefully before initial operation; 

2.

 

This photocell is without any fuse, so Please make sure the power is off before installation; 

3.

 

Only used this system that do not cause any danger life or property during the running failure or its security risks eliminated; 

4.

 

Please guarantee the products used in effective working range.

 

III.

 

Picture Display

 

  

 Wiring diagram•                                     Size 

IV.

 

Installation instruction

 

4.1 

Receive module J2 in pic 3 is the option switch of photocell switch.

 

4.1.1

 When the short circuit cap on NO, The photocell will be Normal Open.

 

4.1.2

 

When the short circuit cap on NC, the photocell will be normal closed.

 

4.2.

 Installation 

4.2.1

The photocells should be installed more than 20cm above the ground (to avoid reflection), and the distance between emitter 

and receiver shall be more than 50cm. 

 4.2.2

 End user should install the photocell on the back of the direct sunlight or other strong light source (±5º) to keep photocell 

work well steadily. 

4.2.3

 Avoid installing other infrared photocell emitters within the effective distance of receiver 

  4.2.4

 If the end user need to install other photocells in one same straight line , the receivers could be installed in the two ends and 

the emitters could be back-to-back installed 

 4.2.5

 Stable installation could avoid the signal of emitter and receiver skewing due to lightly vibrate and the malfunction. 

 4.2.6 

Connect  the  power  after  the  inspection,  when  short  circuit  cap  at  NO,  emitter  module  LED  turns  on,  receiver 

module  LED  turns  on,  receiver  module  contact  at  off;  when  make  the  cap  of  emitter  and  receiver  in  alignment,  receiver 

module LED is off, NC/NO is on; when something or someone shelter the sensor, receiver module LED will turn on , NC/NO 

contact is off. When short circuit cap at NC, the state of NO/NO is opposite to the above phenomenon

 