F5010 Flash lamp user manual Version: A5
F5010 Flash lamp user manual
I.
Safety Instruction
1.
For security, please read the user manual carefully before initial operation;
2.
Please be sure the power is off before connecting, the product is produced without fuse;
3.
This system must not endanger life or property during the running failure or its security risks have
been eliminated
II.
Technical Specification
1.
working voltage
:
12-24VAC/DC
2.
Loading capacity
:
<2.5W
3.
Flicker Frequency
:
1HZ
4.
Working temperature
:
-20º
~
+60
℃
5.
IP Level: IP54
6
.
Size
:
φ90* 125mm
7
.
Weight
:
142g
III.
Connecting Instruction
1.
Connect the wire with power supply 12-24VAC or 12-24VDC.
2.
Antenna is for connecting to extend the effective distance of controller
IV.
Instructions
4.1
LED will flicker in 1HZ after power on
4.2
JP1 switch
It’s the switch for switching LED in flickering or lighting,
When JP1 at FLASH, LED will flicker in 1Hz after power on;
When JP1 at NO FLASH, LED will light after power on
V.
Installation
1
.
Open the package and take out
the accessories for installation.
2
.