HIKVISION iDS-7204AHQHI-M1 Скачать руководство пользователя страница 28

Smart ATM Protection System Quick Start Guide

 

 

28 

 

Figure 3-4

 

Set Advanced Parameters (2) 

 

Go to Device Management > Remote Configuration > VCA Config > Advanced 
Configuration > Parameters 
to adjust Sensitivity (Abnormal) to 4 or 5. 5 means enabling 
the enhanced mode. 

 

 

 

 

 

 

04202011091012 

Содержание iDS-7204AHQHI-M1

Страница 1: ...Smart ATM Protection System Quick Start Guide...

Страница 2: ...D AS IS WITH ALL FAULTS AND ERRORS AND HIKVISION MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRI...

Страница 3: ...ode 5 1 3 Camera Installation for Human Face Mode 5 1 4 Typical Incorrect Installation of Human Face Mode 6 Chapter 2 Smart ATM Configuration via iVMS 4200 Client 8 2 1 Smart ATM Resources Allocation...

Страница 4: ...rt analysis of the facial characteristics of the operators of ATM The human face mode is used independently by default You can select the camera in human face mode linked with panel mode via configuri...

Страница 5: ...e human face should be in the center of the monitoring filed The proportion of the human face width and height in the image should be in the range of 0 15 0 15 to 0 55 0 55 The optimum human face size...

Страница 6: ...display the complete faces of human with heights from 1 40 m to 2 0 m The typical human face image is shown as below Figure 1 2 Camera Installation for Human Face Mode 1 4 Typical Incorrect Installat...

Страница 7: ...Quick Start Guide 7 3 The installation position of the pinhole camera on the ATM is too high It can only monitor the head top or forehead of the operator without monitoring the whole face Adjust the c...

Страница 8: ...uman face mode for analog channel s You shall allocate smart ATM mode s to analog camera s before smart ATM configuration Before you start Add the ATM DVR to iVMS 4200 Client Click on Device Managemen...

Страница 9: ...a s for panel mode or face mode as your desire You can view the available ATM resource information in Resource Information Step 8 Optional Check or uncheck the modes to enable or disable the smart ATM...

Страница 10: ...ls Step 1 Click VCA Config Step 2 Select the camera you have allocated for panel mode The basic device information and VCA type will be displayed on the right Figure 2 3 Panel Mode Step 3 Configure ca...

Страница 11: ...Smart ATM Protection System Quick Start Guide 11 Figure 2 4 Capture and Display Configuration Step 4 Configure scene 1 Click Scene and Calibration 2 Configure the scene parameters...

Страница 12: ...ugh the wall ATM on the street select Outdoor Figure 2 6 Mounting Location Mounting Type The mounting type of the camera Pinhole and Ceiling are selectable The pinhole type is applicable to the camera...

Страница 13: ...as below Figure 2 8 Standing Region Contained in Scene 3 Click Save to save the settings Step 5 Optional Configure the shield region You can configure shield regions to avoid the influences of LCD or...

Страница 14: ...t Type as your desire 4 Set other related parameters such as Duration and Sensitivity 5 Click to draw the entrance region which is the standing region of the operator 6 For Operation Timeout Sticking...

Страница 15: ...schedule 1 Click Arming Schedule 2 Select a rule from Arming Schedule 3 Draw the arming schedule for each day in the week Table 2 1 Icon Description Icon Description Copy the schedule to other days C...

Страница 16: ...o save the settings Figure 2 11 Arming Schedule Configuration Step 8 Configure the linkage action 1 Click Linkage Action 2 Select a rule from Rule List 3 Set Linage Action Alarm Duration Alarm Output...

Страница 17: ...n Configuration Step 9 Optional Configure advanced parameters 1 Click Advanced Configuration 2 Click Parameters 3 Set the advanced parameters of panel mode False Alarm Filter of Sticking Scrip It is e...

Страница 18: ...d wearing sunglasses detection Normal human face detection When a person is operating before the ATM the camera will capture the detected normal human face Abnormal human face detection If a person is...

Страница 19: ...nfig Step 2 Select the camera you have allocated for human face mode The basic device information and VCA type will be displayed on the right Step 3 Configure capture and display Refer to 2 2 1 Panel...

Страница 20: ...ing mobile phone alarm will be triggered respectively The normal face alarm abnormal face alarm and wearing sunglasses alarm of one target will be triggered once For example if one person with normal...

Страница 21: ...ault parameters 24 hours Operation Timeout Panel Mode Same with Sticking Scrip Default parameters It is suggested to arm at night Normal Human Face Human Face Mode You can set full screen as the detec...

Страница 22: ...e default value is 3 and the larger the value is the more sensitive the detection will be Using Mobile Phone Human Face Mode You can set full screen as the detection region Sensitivity 1 5 The default...

Страница 23: ...ra will connect human body detection sensor to judge if there is a person or not If the camera does not connect the sensor it should be closed 2 The DVR does not alarm when sticking scrip or installin...

Страница 24: ...he scrip is removed no matter in what kinds of conditions you can enable the installing scanner rule which will trigger alarm no matter the scrip is stuck or removed 6 Sticking scrip triggers many fal...

Страница 25: ...Management Remote Configuration VCA Config select the camera you have allocated for human face mode and then go to Advanced Configuration Parameters Set Index No to 65538 and its default Index Value i...

Страница 26: ...etection region to exiting the region should exceed 20 s If you want to simulate different kinds of events quickly the time interval of simulating different events should exceed 1 minute Or go to Devi...

Страница 27: ...3 Set Advanced Parameters 1 4 Enter 65538 in Index No text filed to set the alarm time threshold 5 Enter Index Value according to the actual conditions The default value is 30 s and you can set it in...

Страница 28: ...Start Guide 28 Figure 3 4 Set Advanced Parameters 2 Go to Device Management Remote Configuration VCA Config Advanced Configuration Parameters to adjust Sensitivity Abnormal to 4 or 5 5 means enabling...

Страница 29: ...Smart ATM Protection System Quick Start Guide 29 UD16485B...

Отзывы: