It ranges from 5 seconds to 60 seconds, and 20 seconds is the default. If the Hik IP
Receiver Pro dose not receive the response from the ARC in this period, it indicates that no
response has been sent to the Hik IP Receiver Pro.
Attempts
It ranges from one time to 10 times, and 3 times is the default. If the Hik IP Receiver Pro
dose not receive the response from the ARC during the response timeout period, the Hik
IP Receiver Pro will attempt to retransmit the message.
Private
Hik IP Receiver Pro Heartbeat Interval
If you select Private as the protocol type, check Enable Hik IP Receiver Pro Heartbeat to
enable heartbeat between theARC and the Hik IP Receiver Pro. It ranges from 10 to 65535
seconds. It is 30 seconds by default.
5. Click Save.
●
Automation Status: For Sur-Gard protocol, the status means whether the Hik IP Receiver Pro
can receive data from the ARC, which supports Sur-Gard protocol.
○
For Server mode of TCP/IP interface, if the data is received normally, the IP address and port
number of the ARC and Connected will be displayed; For Client mode of TCP/IP interface, if
the data is received normally, Connected will be displayed.
○
For RS-232 interface, if the data is received normally, the serial port number of Hik IP
Receiver Pro and Connected will be displayed.
○
If the data cannot be received, it is shown as Not Connected.
●
Connect Status: For Ademco 685 protocol, Manitou protocol, and SBN protocol, the status
means whether the Hik IP Receiver Pro can receive data from theARC, which supports Ademco
685 protocol, Manitou protocol, and SBN protocol.
●
○
For Ademco 685 protocol, if the data is received normally, the serial port number of Hik IP
Receiver Pro and Connected will be displayed.
○
For Manitou protocol and SBN protocol, if the data is received normally, it is shown as
Connected.
○
If the data cannot be received, it is shown as Not Connected.
6.2 Search History Event
You can search history events which are received by Hik IP Receiver Pro via device account ID and
alarm time. After searching, you can view event source, event code, triggering time, etc.
Steps
1. On the Automation Output page, click Event Monitor to enter the Historical Event page.
2. Optional: Check Automatic Refresh to automatically refresh the event list.
3. Enter account ID.
4. Click Triggering Time field to set the start time and end time.
Hik IP Receiver Pro User Manual
37
Содержание Hik IP Receiver Pro
Страница 1: ...Hik IP Receiver Pro User Manual...