HIKVISION DS-TDSB00-EKT Скачать руководство пользователя страница 7

Fall Detection Radar • User Manual 

 

Installation Requirements 

Install the device on the wall at a height of 2 m. Make sure that the device is centered horizontally 
in the detection area and there is no obstruction in front of it. Refer to the figures below for the 
device installation overview. 

 

     

 

DS-TDSB00-EKT/4m Radar Installation Overview 

Brown 

GND 

Power ground 

Содержание DS-TDSB00-EKT

Страница 1: ...0 DS TDSB00 EKT 4m Fall Detection Radar User Manual...

Страница 2: ...CLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIG...

Страница 3: ...ides additional information to emphasize or supplement important points of the main text Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss per...

Страница 4: ...Overview 2 Cables Description 2 Installation Requirements 3 Chapter 2 Software Instruction 4 Device Connection 4 2 1 1 Connection via Wi Fi 4 2 1 2 Connection via RS 485 5 Parameter Settings 5 2 2 2 R...

Страница 5: ...re High detection accuracy and low false alarm rate Target tracking Remote and non contact posture detection Small size light and easy installation Specification Refer to the table below for the devic...

Страница 6: ...ance Cables Description Refer to the table below for the cables description DS TDSB00 EKT 4m Fall Detection Radar Cables Description Consumption 2 4 W Working Temperature 40 C to 50 C 40 F to 122 F No...

Страница 7: ...on the wall at a height of 2 m Make sure that the device is centered horizontally in the detection area and there is no obstruction in front of it Refer to the figures below for the device installatio...

Страница 8: ...e radar via Wi Fi Before You Start Power on the radar 12 V Connect your computer to the radar AP hotspot SSID format IRS60_xxxx Default password abcd1234 Use ping command to test if the computer is co...

Страница 9: ...radar via the serial port Open the IRS60 3 Radar PC tool Click Connection Settings Select Serial Port Select Port Set BaudRate as 115200 Stop bit as 1 and Data bit as 8 No parity Click Confirm Parame...

Страница 10: ...on to view the software version Go to Parameter Settings Delay Time to set the delay time If the radar detects the target person fell and stood up within the set delay time it will not alarm Otherwise...

Страница 11: ...off and does not receive wakeup command after powered on again then it will still be standby mode Awake If the radar is powered off the awake mode will be kept after it is powered on again Falling Ind...

Страница 12: ...F1 button on the keyboard Menu Page Enter IP Address and Radar Port IP address 192 168 4 1 radar port 6666 Click Connect Click Browse to select the firmware to be upgraded Select Network Segment as t...

Страница 13: ...Manual 9 Click Confirm Click Start Update Upgrade Radar Network Configuration You can set the radar network Open IRS60 3 Radar PC tool Press F2 button on the keyboard Enter IP Address and Port IP addr...

Страница 14: ...onfiguration Click Connect Set Work Mode as 3 Click Set Set AP Router SSID and AP Router PWD AP Router SSID means the router name AP Router PWD means the router password Set DHCPC as 0 Set IP Netmask...

Страница 15: ...Fall Detection Radar User Manual 11 AP SSID means the Wi Fi name AP PWD means the Wi Fi password Set AP Click Set Set Device ID as an integer range 1 to 999999999...

Страница 16: ...evice Information Set data report type as 0 Set service IP as Hikcentral Pro service IP Set service PORT as 20000 Set radar debug PORT as 6666 Set radar Passthrough data PORT as 20000 Set report inter...

Страница 17: ...0...

Отзывы: