DS-PRI120 Security Radar User Manual
UM DS-PRI120 091720NA
61
calibrating. If the calibration points are error, calibrate again.
Check if the calibration positions are equally distributed when you set the multi-point calibration.
Do not move the speed dome manually after the calibration. If the speed dome is manually moved, reset the
initial position of the speed dome and calibrate again.
D.5
How To Solve the Problem that No Reference Point Is on the Frame While
Setting the Speed Dome Initial Position?
Answer: If the speed dome is tilted, it may cause the reference point to be above the center of the frame or
outside the frame while setting the speed dome initial position. In this case, adjust the maximum elevation
angle of the speed dome as follows:
1.
Enter the IP address of the speed dome in the Web browser to enter the Web client.
2.
Click
to expand the PTZ list on the
Live View
page, and then click to enter the main menu of the speed
dome.
Figure D-1 The Main Menu of Speed Dome
You can adjust the cursor for menu selection by clicking the up and down direction keys in
the PTZ list, and click to enter the selected item.
3.
Adjust the cursor to
System Settings
in the main menu and click , then adjust the cursor to
Motion
and
click to enter the page.
Figure D-2 Motion