22
Digit
(RW1)
1 2 3
4
5
6
7 8
Room No. of
F1
F2
F3
F4.
F5
* * *
OFF
ON
ON
* *
73-
84
37-
42
25-
28
19-
21
13-
14
* * *
ON
ON
ON
* *
85-
96
43-
48
29-
32
22-
24
15-
16
* means irrelevant, ON means 1, OFF means 0.
Digit 4, Digit5 and Digit 6 (RW1) are set as OFF by default. When Digit4 and Digit5 are
set as OFF, it means 1 floor with 12 households.
For example, if you set the device as the table below, then the Room No. are 13, 14,
15, 16, 17, 18, 19, 20, 21, 22, 23 and 24.
Table 5-5
RW1 Configuration Example of DS-KAD312( for More than 1 Distributor)
Digit
(RW1)
1
2
3
4
5
6
7
8
Status
OFF
OFF
OFF
ON
OFF
OFF
*
ON
5.2
Configure RW 2
RW2 is used to set the start floor No.. The configuration as below:
Set the status (ON/OFF) of each digit to define the start floor. The sum of the binary
values of digits is the start floor No..
Table 5-6
RW2 Configuration of DS-KAD312
Digit
(RW2)
1
2
3
4
5
6
7
8
Binary
Value
1
2
4
8
16
32
64
128
Status
ON/OFF
ON/OFF
ON/OFF ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF