Access Controller
·
User Manual
53
2.
Select the APN name as CMNET or UNINET.
3.
Input the SIM Card No.
4.
Select the center group in the dropdown list.
5.
Input the IP address and port No.
6.
Select the protocol type as EHome. By default, the port No. for EHome is 7660.
7.
Set an account name for the network center. A consistent account should be used in one
platform.
8.
Click
Save
button to save parameters.
Note:
The port No. of the wireless network and wired network should be consistent with the port
No. of EHome.
7.4.5
Capture Settings
You can set the parameters of capture linkage and manual capture.
Select the device in the device list, and click
Modify
to pop up the modifying device information
window.
Click
Capture Settings
tab to enter the capture settings interface.
Notes:
The
Capture Settings
should be supported by the device.
Before setting the capture setting, you should configure the storage server for picture storage.
Linked Capture
Steps:
1.
Select the
Linked Capture
tab.
2.
Set the linked capture times once triggered.
Set the capture interval according to the capture times.
3.
Click
Save
to save the settings.
Manual Capture
Steps:
1.
Select the
Manual Capture
tab.
Содержание DS-K2600-G Series
Страница 1: ...DS K2600 G Series Access Controller User Manual UD05678B...
Страница 27: ...Access Controller User Manual 18 4 4 Connecting the External Alarm Device 4 5 Door Button Wiring Diagram...
Страница 28: ...Access Controller User Manual 19 4 6 The Connection of Magnetics Detection 4 7 Connecting Power Supply...
Страница 30: ...Access Controller User Manual 21 4 9 Fire Alarm Module Wiring...
Страница 33: ...Access Controller User Manual 24...
Страница 125: ...Access Controller User Manual 116...