![HIKVISION DS-K1T690 Series Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/hikvision/ds-k1t690-series/ds-k1t690-series_user-manual_2133918131.webp)
Figure 8-20 Black Body Settings
2. Enable black body correction function.
3. Put a black body in front of the camera. Make sure there are no other objects between the
camera and the black body.
4. Set the distance between the black body and the camera (straight line), the emissivity of the
black body, and the temperature unit.
Note
The black body's temperature is fixed.
5. Click Calibrate, and draw the black body's position on the page. When + is displayed on the black
body on the screen, the black body is calibrated.
6. Click Save.
Draw Temperature Measurement Area
Click Configuration → Temperature → Temperature Measurement Area .
Drag the yellow frame in the live video to adjust the measurement area. Only the temperature
within the area can be measured by the system.
Click Save to save the settings.
Click
or to record videos or capture pictures.
8.6.25 Set Biometric Parameters