Chapter 4 Wiring
You can connect the RS-485 terminal with the RS-485 card reader, connect the NC and COM
terminal with the door lock, connect the SENSOR terminal with the door contact, the BTN/GND
terminal with the exit button, and connect the Wiegand terminal with the Wiegand card reader or
the access controller.
If connect the WIEGAND terminal with the access controller, the face recognition terminal can
transmit the authentication information to the access controller and the access controller can
judge whether to open the door or not.
Note
If the cable size is 18 AWG, the distance between the power supply and the device should be no
more than 60 m when wiring a single device. And the door lock and the other peripherals should
connect to a 12 VDC external power supply. If connecting to a 12 VDC door lock, the distance
between the power supply and the device should be 30 m.
4.1 Terminal Description
The terminals contains power input, RS-485, Wiegand output, and door lock.
The descriptions of the terminals are as follows:
Table 4-1 Terminal Descriptions
Group
No.
Function
Color
Name
Description
Group A
A1
Power Input
Red
+12 V
12 VDC Power
Supply
A2
Black
GND
Ground
Group B
B1
RS-485
Yellow
485+
RS-485 Wiring
B2
Blue
485-
B3
Red/Black
GND
Ground
Group C
C1
Wiegand
Green
W0
Wiegand
Wiring 0
C2
White
W1
Wiegand
Wiring 1
C3
White/Black
GND
Ground
Group D
D1
Door Lock
White/Purple NC
Lock Wiring
(NC)
DS-K1T341C Series Face Recognition Terminal User Manual