Appendix B. Input Types
Table B-1 Input Types
Input Types
Operations
Instant Zone
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response Trigger the system sound and siren.
Voice Prompt: Zone X alarm.
Perimeter Zone
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response: Trigger the system sound and siren. There is a
configurable interval between alarm and siren output, which
allows you to check the alarm and cancel the siren output during
the interval.
Voice Prompt: Zone X perimeter alarm.
Delayed Zone
The system provides you time to leave through or enter the
defense area without alarm.
Audible Response: Trigger the system sound and siren.
Voice Prompt: Zone X alarm.
Follow Zone
The zone acts as delayed zone when it detects triggering event
during system Entry Delay, while it acts as instant zone
otherwise.
Audible Response: Trigger the system sound and siren.
Voice Prompt: Zone X follow alarm.
24H Silence Zone
The zone activates all the time without any sound/siren output
when alarm occurs.
Audible Response: No system sound (voice prompt or siren).
Panic Zone
The zone activates all the time.
Audible Response: Trigger the system sound and siren.
Voice Prompt: Zone X panic alarm.
Fire Zone
The zone activates all the time with sound/siren output when
alarm occurs.
Audible Response: Trigger the system sound and siren.
Voice Prompt: Zone X fire alarm.
AX Security Control Panel
99
Содержание AX DS-PWA32-H
Страница 1: ...AX Security Control Panel...
Страница 120: ...Authentication Code Adding Editing Location x x x Exchange Programing Firmware x x AX Security Control Panel 111...