X86 Open Platform
·
User Manual
62
If the input device is NPN signal (suspended or power negative), IN_COM should be
connected with input device power positive, and signal line with corresponding input
interface.
If the input device is PNP signal (suspended or power positive), IN_COM should be
connected with input device power negative, and signal line with corresponding input
interface.
I/O interface output is open-circuit output, as shown below. Input voltage ranges from 5
VDC to 30 VDC, and current cannot exceed 200 mA.
Expansion Interface
Board
Smart Camera
12-pin Power Cable
OUT_COM
OUT0/1/2
Figure 11-6
I/O Output Wiring
If the output device is NPN signal (suspended or power negative), OUT_COM should be connected
with input device power positive, and signal line with corresponding input interface.
If the output device is PNP signal (suspended or power positive), the OUT_COM should be
connected with input device power negative, and signal line with corresponding input interface.
Do not directly connect with inductive load (e.g. relay, DC motor, etc.) when outputting.
11.5 Update Firmware
You can update the firmware of the interface expansion module via IO Controller application.
Steps:
1.
Right click MVS icon, and select Open file location.
2.
Go back 2 levels of directory to find the Development folder.
3.
Open IOController application in the location directory Bin\Acypu\ IOController.
4.
Click Update Firmware, select updating file, and click Update.
Содержание X86
Страница 1: ...X86 Open Platform User Manual ...
Страница 7: ...X86 Open Platform User Manual vii E mail tech_support hikrobotics com Website en hikrobotics com ...
Страница 38: ...X86 Open Platform User Manual 28 Figure 6 3 Set Output Delay Duration or Ahead Time ...
Страница 67: ...X86 Open Platform User Manual 57 Figure 10 17 Select MVision 6 Connect device and obtain images ...
Страница 75: ...UD15058B ...