Figure 7-17
Level Trigger in Frame Trigger
Set Trigger Activation in Line Trigger
In the line trigger mode, the trigger activation is related with Exposure Mode.
When Timed is selected as Exposure Mode, you can select Rising Edge, Falling Edge or Any
Edge as Trigger Activation, and Exposure Auto and Exposure Time determine the exposure
time.
When Trigger Width or Timed is selected as Exposure Mode, you can select Level Low or
Level High as Trigger Activation, and exposure time is determined by the duration of the level
signal only.
Figure 7-18
Set Trigger Activation in Line Trigger
The trigger width function may differ by camera models.
7.7.3 Trigger Delay
The trigger delay function allows the camera to add a delay between the receipt of trigger signal
and the moment the trigger becomes active. Its sequence diagram is shown below.