Camera Link Line Scan Camera
·
User Manual
22
Trigger
Source
Supported
Trigger Mode
Parameter
Parameter
Value
Principle
Free Trigger
Frame trigger or
line trigger
Acquisition
Control >
Trigger Source
Anyway
Use trigger sources mentioned
above to send trigger signal to the
camera to acquire images.
The trigger source may differ by camera models.
These trigger sources are valid only the frame trigger mode, line trigger mode or line + frame
trigger mode is enabled.
7.6.1 Set Software Trigger
The camera supports software trigger. When the software trigger is selected, the client software
sends commands to the camera via Camera Link cable to acquire and transmit images.
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Frame Burst Start as Trigger Selector, and On as Trigger Mode.
3.
Select Software as Trigger Source, and click Execute in Trigger Software to send trigger
commands.
Figure 7-5
Set Software Trigger
7.6.2 Set Hardware Trigger
If the camera enables the frame trigger or line trigger, you can select specific lines as trigger source
to enable hardware trigger. At this time, external devices send commands to the camera to acquire
images.
The specific hardware trigger sources may differ by camera models. Here we take Line 0 as trigger
source as an example. Refer to the camera you got for the actual condition.