Camera Link Line Scan Camera
·
User Manual
19
Figure 7-2
Set Scan Mode
7.3 Set Frame Timeout
The frame timeout function may differ by camera models.
If the frame timeout function is disabled, the camera outputs one frame image after its
outputted line quantity reaches the configured height value, and the camera will wait line
quantity data if the outputted line quantity does not reach the configured height value.
If the frame timeout function is enabled, the camera outputs one frame image after its
outputted line quantity reaches the configured height value in the configured frame timeout
time.
Click Acquisition Control, enable Frame Timeout Enable, and set Frame Timeout Time according
to actual demands.
Figure 7-3
Set Frame Timeout
7.4 Set Line Discard Function
The line discard function may differ by camera models.
The line discard function is used to make sure that the quantity of external control signals is
matched with that of image output lines. You can go to Acquisition Control, and enable Abnormal
Line Enable according to actual demands.
Figure 7-4
Set Line Discard Function