When the NPN single-ended signal source provides signal, the wiring is shown below.
NPN Single-
Ended
Signal
Source
Camera Power
Signal Source Power
PWR
VCC
Camera Power Ground
GND
LINE*P
Signal Line
R (1 K
Ω to 10 KΩ)
LINE*N
Hang
Signal Source Power Ground
Figure 9-16
NPN Single-Ended Input Wiring
9.4 Output Wiring
The four bi-directional I/O of MV-CL022-91GM/GC, MV-CL042-91GM/GC, and 8K cameras can be
set as output signals to trigger other devices.
The wiring may differ by I/O signals used as differential output or single-ended output.
Here we take one type of GigE line scan cameras as an example to introduce the input wiring.
Refer to the actual camera you got for specific appearance.
When I/O signals are used as differential output, the wiring is shown below.
Triggered
Device
Camera Power
PWR
Camera Power Ground
GND
LINE*P
OUT A
LINE*N
OUT Ã
Power Ground of Trigger Device
Figure 9-17
Differential Output Wiring
When I/O signals are used as single-ended output, the wirings are different according to the