Table 3-1 Input Electrical Feature
Parameter Name
Parameter Symbol
Value
Input Logic Level Low
VL
1.5 VDC
Input Logic Level High
VH
2 VDC
Input Falling Delay
TDF
81.6
μs
Input Rising Delay
TDR
7
μs
3.2 Output Signal
The device's LineOut 0/1/2 is opto-isolated output, and their internal circuit is as follows.
Note
●
The output voltage ranges from 5 VDC to 30 VDC.
●
The maximum current is 25 mA.
●
Do not directly connect with inductive load (e.g. DC motor, etc.) when outputting.
Figure 3-3 Internal Circuit of Output Signal
Figure 3-4 Output Logic Level
Note
If the external voltage and resistance change, the corresponding current of output signal and
output logic level low may differ.