CoaXPress Area Scan Camera
·
User Manual
56
Table 11-2
Exposure Method and Principle
Exposure Method
Principle
Off
The camera exposures according to the value configured by user in
Exposure Time (µs).
Once
The camera adjusts the exposure time automatically according to the
image brightness. After adjusting, it will switch to Off Mode.
Continuous
The camera adjusts the exposure time continuously according to the
image brightness.
When the Exposure Auto is set as Off, you can enter Exposure Time manually. When the Exposure
Auto is set as Once or Continuous, the exposure time should be within the range of Auto Exposure
Time Lower Limit and Auto Exposure Time Upper Limit.
Figure 11-17
Set Exposure Time under Once or Continuous Mode
If the camera is under Continuous exposure method, and once external trigger mode is enabled,
the camera will automatically switch to Off exposure method.
11.11 Set HDR
The HDR function may differ by camera models.
The camera supports HDR (High Dynamic Range) function that the camera acquires images based
on customized settings, and each with its own exposure time, gain and white balance.
Steps:
1.
Click Acquisition Control > HDR Selector, and select 0 to 7 as HDR Selector according to actual
demands.