background image

 

 

VII Page  6 of 15 

caused by the use of the tool and also of trip hazards caused by the air line or hydraulic 
hose. 

-  Proceed with care in unfamiliar surr oundings. Hidden hazards, such as electricity or other 

utility lines, can exist. 

-  The power tool is not intended for use in potentially explosive atmospheres and is not 

insulated against coming into contact with electric power.  

-  Make sure there are no el ectrical cables, gas pipes, etc., that can cause a hazard if 

damaged by use of the tool.  

 

DF

Dust and fume hazards 

-  Dust and fumes generated when using power tools can cause ill health (for example, 

cancer, birth defects, asthma and/or dermatitis); risk assessment and implementation of 
appropriate controls for these hazards are essential.  

-  Risk assessment should include dust created by the use of the tool and the potential for 

disturbing existing dust. 

-  Operate and maintain the tool as recommended in these instructions, to minimize dust 

and fume emissions. 

-  Direct the exhaust so as to min imize disturbance of dust in a dust -filled environment. 
-  Where dust or fumes are created, the priority shall be to control them at the point of 

emission. 

-  All integral features or accessories for the collection, extraction or suppression of airborne 

dust or fumes should be correctly used and maintained in accordance with the 
manufacturer's instructions. 

-  Select, maintain and replace the consumable/inserted tool as recommended in the 

instruction handbook to prevent an unnecessary increase in dust or fumes . 

-  Use respiratory protection in accordance with employer's instructions and as required by 

occupational health and safety regulations.  

 

NH

Noise hazards 

-  Exposure to high noise levels can cause permanent, disabling, hearing loss and other 

problems, such as tinnitus (ringing, buzzing, whistling or humming in the ears).  Therefore, 
risk assessment and implementation of appropriate control s for these hazards are 
essential. 

-  Appropriate controls to reduce the risk may include actions such as damping materials to 

prevent workpieces from “ringing”. 

-  Use hearing protection in accordance with employer's instructions and as required by 

occupational health and safety regulations.  

-  Operate and maintain the power tool as recommended in the instruction handbook, to 

prevent an unnecessary increase in noise levels.  

-  Select, maintain and replace the consumable/inserted tool as recommended in the 

WH

Workplace hazards 

-  Slips, trips and falls are major causes of workplace injury. Be aware of slippery surfaces 

 

Содержание WR14A

Страница 1: ...WR14A WR27A...

Страница 2: ...Impact Rachet Wrenches It is intended for lightening loosening or installing uninstalling of threaded fasteners with appropriate power socket wrenches ir driver bits...

Страница 3: ...ainer hammers needle scalers by the bit holder screwdrivers by the collet die grinders by the flange set grinders blade holder saws or firmly attached to the anvil impact ratchet wrenches or the pad s...

Страница 4: ...ol Failure to do so can result in serious bo dily injury Only qualified and trained operators should install adjust or use the power tool Do not modify this power tool Modifications can reduce the eff...

Страница 5: ...clothing are recommended If the power tool is fixed to a suspension device makesure that the fixation is secure RM Repetitive motions hazards When using a power tool to perform work related activities...

Страница 6: ...ll integral features or accessories for the collection extraction or suppression of airborne dust or fumes should be correctly used and maintained in accordance with the manufacturer s instructions Se...

Страница 7: ...se severe injury Always shut off air supply drain hose of air pressure and disconnect tool from air supply when not in use before changing accessories or when making repairs Never direct air at yourse...

Страница 8: ...use in confined spaces and beware of crushing hands between tool and workpiece especially when unscrewing Do not touch sockets or accessories during impacting as this increases the risk of cuts burns...

Страница 9: ...ength x Height x Width 184mm x 205mm x 68mm 216mm x 233mm x 84mm A weighted sound pressure level at workstation Lpa 92 8dB 102 5dB A weighted sound power level Lwa 0 1 3 8dB 113 5dB Vibration value ac...

Страница 10: ...pressed air connection and a quick lock coupling must be at least 20 cm in length If fitted too close to the device a quick lock coupling may fail whiplashing hoses can cause serious injury as a resul...

Страница 11: ...ions for the waste disposal Always use the accessories recommended by your distributor Always disconnect the air supply before performing any maintenance on the tool Lubrication Air tools require regu...