15
Enforcer V10 Programming Guide
7.
Input Description’ will be displayed. Press
to enter a name and location
for this device or press
to return to input selection.
8.
Enter Name’ will be displayed. Enter the name of the input and press
. This
will be displayed if it is activated or when a fault occurs.
9.
‘Enter Location’ will be displayed. Enter the location of the input and press
. This will be displayed if it is activated or when a fault occurs after the
name of the input has been shown.
10. Press
[
or
]
to select another input to program (01-66) or press the
key to return to the Engineer menu.
CHOOSE MODE
If a Enforcer I/O board or any Zone Expander Module (Input Expander or ZEM) are used, the resistance, EOL mode
and response time of the inputs can be programmed.
Please note: Alarm 4K7, Tamper 2K2 must be selected if wiring double pole to an expander.
EOL Range (End of Line Range)
EOL Range
Programs the panel to operate with different resistor values
[0] Alarm: 1K, Tamper: 1K.
[1] Alarm: 4K7, Tamper: 2K2.
[2] Alarm: 4K7, Tamper: 4K7.
[2] Wide range.
EOL Mode
EOL Mode programs all input expanders to operate as:
[0] Single End of Line (SEOL).
[1] Double End of Line (DEOL).
Input Response Time
Input Response time programs the time that an input trigger must be present before the Enforcer system generates
an alarm.
[01] - [30] = 100ms to 3000ms
Please note: Settings above (>) 400ms do not comply with PD 6662 / EN 50131.
Choose Mode Programming
1.
Press
or
to scroll to ‘CHOOSE MODE’. Press
.
2.
Press
[
or
]
to select the ‘EOL Range’ for all wired inputs*. Press
.
3.
Press
[
or
]
to select the ‘EOL Mode’ for all wired inputs*. Press
.
4.
Press
[
or
]
to select the ‘Input Response Time’ for all wired inputs*. Press
to return to the Engineer Menu.
*On the I/O board and the expanders