APPLIANCE OPERATION MANUAL

Contact us for your nearest Highland Agent:

PRK&WS Pty Ltd
83 Bangholme Road, Dandenong South
Victoria Australia 3175
——

Australian Sales and Services:

+61 (0)3 9700 9100
[email protected]
www.highland.com.au

Last Updated- March 24th, 2016 -  

Highland_Cooktop_Manual.Indd

Содержание HIG301B1 L

Страница 1: ...your nearest Highland Agent PRK WS Pty Ltd 83 Bangholme Road Dandenong South Victoria Australia 3175 Australian Sales and Services 61 0 3 9700 9100 info prks com au www highland com au Last Updated Ma...

Страница 2: ...MED LOW TO USE YOUR NEW HIGHLAND COOKTOP 1 Push down on the knob to engage ignition system 2 Turn to the max position to activate gas 3 Continue pressing down on knob firmly holds this position for 2...

Страница 3: ...s own discretion may replace or repair any defective component s to affect a repair due to any faulty workmanship and material The warranty does not cover breakage of outer glass panels attributed to...

Страница 4: ...BURNERS 14 CARE AND MAINTENANCE 15 FAULT FINDING ABNORMAL OPERATION 16 INSTALLATION INSTRUCTIONS 17 18 SERVICING INSTRUCTIONS 19 21 PROCEDURE FOR CONVERTING NATURAL GAS TO LP GAS 22 PRODUCT SPECIFICAT...

Страница 5: ...iances to meet your cooking needs NOTE ALL MATERIAL SURROUNDING THE INSTALLATION MUST BE ABLE TO WITHSTAND TEMPERATURES OF 95 C DURING PERIODS OF OPERATION CERTAIN MATERIALS VINYL WRAP MAY SUFFER DAMA...

Страница 6: ...ppliance 4 Do not use the burners as a room heater 5 Do not allow clothing to pass over or near to the flame 6 Do not leave handles of saucepans protruding out into the room or over adjacent burners A...

Страница 7: ...l service agent WARNING IF THE CERAMIC SURFACE IS CRACKED SWITCH OFF TO AVOID THE POSSIBILITY OF ELECTRICAL SHOCK THE GAS OPERATION ____________________________________________________________________...

Страница 8: ...AND CONFIRM THE UNIT HAS POWER 2 Press and hold the control knob down firmly for a full 5 seconds to ensure the flame failure device engages If the flame goes out after you release the knob then the f...

Страница 9: ...fast cost effective and accurate cooking method Induction compatible vessels must be used SAFETY CUT OUT INDUCTION ____________________________________________________________________________________...

Страница 10: ...is accidentally damaged contact your local service agent Only clean the hob in accordance with the cleaning and maintenance instructions Never allow sugar or acidic food stuffs to be spilled onto the...

Страница 11: ...____________________________________________________ The Booster function for the burner is enabled by turning the knob clockwise When this function is enabled the display shows the letter P By means...

Страница 12: ...circuits definitely indicates an anomaly and means that the cook top has not been installed properly or the openings for air circulation are not large enough ERROR TABLE ______________________________...

Страница 13: ...sence of a pan that according to the scale of the EN Standards is one size smaller than the nominal diameter of the burner If no pan is detected or if an unsuitable pan is detected the no pan symbol i...

Страница 14: ...tput but the outer burner is on minimum output SIMMER The burner is operating at lowest output setting LEGEND GAS CONTROL GRAPHICS A B AND C BURNERS ___________________________________________________...

Страница 15: ...not affect the performance of the burners The burners can be re chromed with HIGHLAND s exchange program for a nominal fee The burner cap can be removed and cleaned with a soft bristled brush and warm...

Страница 16: ...PANEL AND NOT ENGAGING THE FLAME FAILURE DEVICE HOLE IN KNOB NEEDS PACKING IF THIS IS A FAULT PRESENT ON THE WOK BURNER REFER TO THE CORRECT ASSEMBLY INSTRUCTIONS UNIT OCCASIONALLY EMITS A SPARK EVEN...

Страница 17: ...the space requirements Clearances For gas cooktops with a FullSpectrum burner due to the high heat output ensure that there is at least 700 mm clearance between the benchtop and the rangehood above o...

Страница 18: ...SERVICING AND REMOVAL 1 For the LP Gas model the gas supply must be regulated to 2 75kPa for Natural Gas regulated to 1kPa A manual shut off valve must be installed in the gas supply line in an access...

Страница 19: ...dels the base fixing clamps need to be removed from below so that the appliance can be raised out of the opening and the screws removed around the sides The stainless steel hob can be removed by takin...

Страница 20: ...e as shown in the following diagram The black sealing tape may present some resistance For models with the ceramic glass stainless steel hobs unscrew as shown in the following diagram The black sealin...

Страница 21: ...gas The left hand screw operates the minimum setting of the main outer burner ring Whereas the right hand screw operates the minimum setting of the auxiliary inner burner ring The other valves feature...

Страница 22: ...ed in the servicing instructions Ensure the Natural gas regulator is replaced with an LP gas regulator usually supplied at the cylinder 3 To convert the burner you will need to replace the main inject...

Страница 23: ...301B1N or LPG HIG301B1L 10 Amp plug connection to 220 240 V Product dimension mm 352 x 405 Cut out dimension mm 378 x 320 TECHNICAL DIAGRAM 405mm 352mm 65mm 378mm 320mm HIG301S1 N L 35 2 CM WIDE STAIN...

Страница 24: ...IG903B1N or LPG HIG903B1L 10 Amp plug connection to 220 240 V Product dimension mm 850 x 405 Cut out dimension mm 817 x 378 TECHNICAL DIAGRAM 850mm 405mm 378mm 817mm 50mm HIG903S1 N L 85 CM WIDE STAIN...

Страница 25: ...ion CONVENIENCE Smooth vitreous enameled cast iron pan supports dishwasher safe for easy cleaning Frameless ceramic glass surface for ease of cleaning HIG604S1 N L 66 CM WIDE STAINLESS STEEL GAS COOKT...

Страница 26: ...lled flame re ignition CONVENIENCE Smooth vitreous enameled cast iron pan supports dishwasher safe for easy cleaning Frameless ceramic glass surface for ease of cleaning HIG906S1 N L 98 5 CM WIDE STAI...

Страница 27: ...cleaning TECHNICAL INFORMATION Available for connection to Natural gas HIXG905B1N or LPG HIXG905B1L 20 Amp plug connection to 220 240 V 5 5 kW max rated load Product dimension mm 1015 x 505 Cut out d...

Страница 28: ...function and 3 2 kW maximum output 1 x 140 mm diameter induction cooking zone with Booster function and 1 8 kW maximum output CONTROLS Solid steel control knobs Electronic ignition box for automatic...

Отзывы: