Tmax is the maximum temperature value measured in the imaging picture. Click
Tmax in the upper left corner to hide or display the Tmax cursor in the picture.
Tmin is the minimum temperature value measured in the imaging picture. Click Tmin
in the upper left corner to hide or display the Tmin cursor in the picture.
T0 is the temperature value measured at the fixed center point in the imaging picture,
and the cursor is fixed at the center of the picture. Click T0 in the upper left corner to
hide or display the T0 cursor in the picture.
T1 is the temperature of the measurement target that the user manually clicks on the
screen at will. If the user does not click on the screen, this cursor will not be displayed.
Click T1 in the upper left corner to close the T1 cursor in the picture.
Photo taking, video recording, playback and other related operations are the same as
that of visible light mode.
Blending Mode
It integrates visible light with thermal imaging picture, and is mainly used for AI
automatic recognition and temperature measurement in this mode.