CHAPTER 3
The Menu System
Studio Command Series User Manual
29
Setting the Lamp Warning Message (LMPL)
This menu option is available in Studio Command 1200 and 700 models only. Use this menu
item to enable your fixture to display the warning message LAMP LIFE ERR when the current
lamp hours exceed 700. With this option enabled, after the current lamp hours exceed 800
hours, the fixture will display the warning message LAMP OUT ERR. Once the lamp is
extinguished, the fixture will no longer strike the lamp until the current lamp is replaced and the
current lamp hours are reset to zero (see Replacing the Lamp on page 58 and Resetting Lamp
Hours (L/RS) (Studio Command 1200/700 models only) on page 40).
To enable the lamp warning message:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the SET menu. Press <Enter> to select.
3. Scroll to the LMPL menu. Press <Enter> to select.
4.
or
Scroll to ON to enable the lamp warning message, or
OFF to disable the lamp warning message.
5. Press <Enter> to store.
Data Loss Shutter Close (DLOS)
Use this menu item to determine how the fixture will react in the event of DMX data loss by
closing the shutter upon Data Loss or keeping the shutter open until shut down. In the Studio
Command 1200/700 model, the fixture responds to a Data Loss by closing the shutter. In Studio
Command H models, the fixture responds to a Data Loss by dousing the lamp.
To select a shutter reaction to data loss:
1. Press and hold <Menu> until AddR appears on the LED display.
2. Scroll to the SET menu. Press <Enter> to select.
3. Scroll to the dLOS menu. Press <Enter> to select.
4.
or
Scroll to LONG to close the shutter (or douse the lamp in H model) only when the
fixture is shut down, or SHRT to close the shutter one second after data loss.
5. Press <Enter> to store.
Содержание Studio Command 1200
Страница 18: ...CHAPTER 1 Product Overview 8 Studio Command Series User Manual...
Страница 30: ...CHAPTER 2 Setup and Configuration 20 Studio Command Series User Manual...
Страница 64: ...CHAPTER 4 Fixture Programming 54 Studio Command Series User Manual...
Страница 72: ...CHAPTER 5 General Maintenance 62 Studio Command Series User Manual...
Страница 82: ...CHAPTER 6 Troubleshooting 72 Studio Command Series User Manual...
Страница 92: ...Appendix A Studio Command DMX Protocol 82 Studio Command Series User Manual...
Страница 102: ...Appendix C 92 Studio Command Series User Manual...
Страница 108: ...Appendix D 98 Studio Command Series User Manual...