Fault Information and Troubleshooting Method

NO

Fault

Code

Fault

Description

Cause and Solutions of Fault

Recovery 

Procedure

1

P0

Hardware

Overcurrent

Motor model is mismatch, please choose 

matching pumps.

UVW three-phase short-circuit 

connection, please rewiring to ensure the 

normal installation of UVW.

Automatically

remove after 30s

2

P43

Phase

Protection

UVW three-phase open circult, please 

rewiring to ensure it reliable contact.

Automatically

remove after 30s

3

P46

Stall

Protection

Motor model is mismatch, please choose 

matching pumps.

Pump extension cord is too long. Please 

reduce the extension cord.

Power is too low, increase the power 

supply.

Pump bearing is stuck, please clean 

pump bearings.

Automatically

remove after 30s

4

P49

Software

Overcurrent

Water pump bearing stuck, clean pump 

bearings.

UVW three-phase short-circuit 

connection, please rewiring to ensure the 

normal installation of UVW.

Automatically

remove after 30s

5

P50

Low Voltage

Protection

The input voltage is too low, please 

distribute power refer to the electrical 

characteristics.

Voltage return to 

normal, remove the 

fault immediately

6

P51

High Voltage

Protection

The input voltage is too low, please 

distribute power refer to the electrical 

characteristics.

Voltage return to 

normal, remove the 

fault immediately

7

P48

Dry-run

Protection

Not all of air in the pump is exhausted, 

cut off the power, re-power and start the 

pump drainage after 30 seconds.

There is no water in the water tank 

waiting for water, it will restart.

Automatically clear 

after 30 minutes or 

re-power to clear

8

P60

High Temperature

Protection

The temperature of controller MCU is more 

than 90

.

Automatically clear 

after the temperature 

is normal

9

E8

Current Sampling 

Failure

Cut off the power and restart after 30 

seconds.

Restart the power

10

PL

Power Shortage

No sunlight, waiting for the sunllight to 

restart.

Solar panel matching error, refer to the 

recommendation to match correctly.

At the first 5 times, it 

will removal after 30 

seconds, and then 

30 minutes to 

rempval

11

ALARM Reverse connection 

protect

Exchange the positive and negative wire.

Restart the power

12

P42

Start fault

1-7 fault, appear continuously for several 

times in 10 minute. Check NO.1-7 fault.

Restart power

10

Содержание HIDRO-SP Series

Страница 1: ...SOLAR POWERED SWIMMING POOL PUMP HIDRO SP Series INSTALLATION AND MAINTENANCE MANUAL Please read this operation manual carefully and keep it for future reference ...

Страница 2: ...el connections are considered low voltage there is still a possibility of electrical shock During the connection stage of the solar panels it is recommended that the panels be covered with dark cloth or cardboard until connections are completes and you are ready to carry out voltage tests Do not switch the power on unless all connectins and voltage readings are correct The pump leaf basket must be...

Страница 3: ...nel Requirements Recommended Power of PV panels watts Rated power of pump watts 1 3 1 6 Example One SP 067 pump Power 500 watt pump needs a minimum of 500 watts multiplied by 1 3 to maximum 1 6 to drive the DC motor 500w 1 3 Minimum Panel wattage required 650w Optimum 800 Watt You may need combinations of series and parallel connections of panels especially for the larger pumps The requied voltage...

Страница 4: ...Solar Panel 200 Watt 36V 36 Volt 400 watt 16 Amp Solar Panel 230 250 Walt VOC 38 44V Hidro SP026 Solar Panel 230 250 Walt VOC 38 44V Panel Battery Motor TL TH WEL COM P P P P W V U X X X X DC FUSE 10 Amp W V U 1 Short Circuit 2 Each sensor must conntact on COM DC FUSE Water Tank Water lever sensor Battery Hidro SP026 Max Lift 9m 30 feet Max flow 6m3 hr Nominal Voltage 24V 200W Min Panel Power 300W...

Страница 5: ...on COM DC FUSE Water Tank Water lever sensor Battery Solar Panel 250 300 Walt VOC 38 44V Solar Panel 250 300 Walt VOC 38 44V Solar Panel 250 300 Walt VOC 38 44V Solar Panel 250 300 Walt VOC 38 44V Hidro SP067 Max Lift 15m 45 feet Max flow 17m3 hr Nominal Voltage 48V 500W Min Panel Power 650W Max Panel Power 1000W Max Voc 100 Volt DC Solar Battery or a combine Pump Connection 2 Hidro SP0120 Max Lif...

Страница 6: ...dicates no water in well MPPT Solar energy running lights twinkling Power Light twinkles when stop working light is constant in runing 2 Key Operation Key Type Function Set key Parameter setting Enter Parameter confirm Up RPM setting key Each time you press the RPM will in crease for one grade In fault state turn off on the fault display Down RPM setting key Each time you press the RPM will decrea...

Страница 7: ...en spin up to full speed within the next 6 seconds NOTE Looking at the motor from the back fan the motor should spin clockwise 6 SWIMMING POOL SKIMMER LOWER SUCTION POOL JET POOL JET Solar DC Pump FILTER HEATER Existing Pool Pump SEPARATION VALVES 1 SKIMMER OUTLET 2 LOWER POOL SUCTION 3 SOLAR POOL PUMP SEPARATION SUCTION SIDE 4 EXISTING AC POOL PUMP SUCTION SIDE 5 SOLAR PUMP EXIST SPEARATION VALVE...

Страница 8: ...en momentarily as warranty will be void Don t use the pump in dirty and or contaminated water Premature wear will not be covered by warranty Don t disassemble the controller There are no user parts inside Do s Strainer basket to be cleaned to prevent the pump from water starvation Do s Install spark arrestor for high voltage spoke Do s Install appropriate AC breakers for panels battery bank Hidro ...

Страница 9: ... seal 24 Motor pad 7 Connection O ring 16 Pump cover 25 Motor 8 Outlet nut 17 Gasket 9 Outlet pipe 18 Screw Hidro SP 1200W Exploded View CHART No ITEM No ITEM No ITEM 1 Hand shank 10 Outlet pipe 19 Guide plate 2 Filter nut 11 Connection O ring 20 Impeller 3 Filter cover 12 Pump body 21 Mechanical seal 4 Filter cover O ring 13 Pump body seal ring 22 Pump cover 5 Filter 14 Guide plate seal ring 23 S...

Страница 10: ...te Q MANUFACTURE CODE VOLTAGE POWER MAX FLOW MAX HEAD OUTLET m 3 h m inch Hidro SP026 24V 200W 6 9 1 5 x 1 5 Hidro SP067 48V 500W 17 15 2 x 2 Hidro SP120 72V 900W 21 19 2 x 2 Hidro SP160 72V 1200W 31 19 3 x 3 9 Total dynamic head H m ...

Страница 11: ...er refer to the electrical characteristics Voltage return to normal remove the fault immediately 6 P51 High Voltage Protection The input voltage is too low please distribute power refer to the electrical characteristics Voltage return to normal remove the fault immediately 7 P48 Dry run Protection Not all of air in the pump is exhausted cut off the power re power and start the pump drainage after ...

Отзывы: