background image

Web-Based Access Control Solution 

ACW2-XN 

Installation Guide 

ACW2XN-902-EN, Rev. A.2 

PLT-03474 A.2 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Introduction 

Product Description 

HID Global's Web-based Access Control Solution for small businesses, ACW2-XN, provides a turnkey 

solution for small facilities. Meet today’s security challenges and benefit from support for state-of-the-art 

identity management and reliability of an enterprise level hardware at a fraction of the cost. 
Reduce risk and response time for lost or stolen credentials. Use a standard web browser to access the 

intuitive management portal. The web-based portal, HID Access Manager,  makes it convenient to 

provision and revoke smart cards without the expense or difficulties of managing physical keys. 
In addition to access and identity management, ACW2-XN provides valuable built-in business tools. Basic 

reporting and full audit logs are available at the touch of a button through the web-based portal. 
Reliable and backed by a strong warranty, HID Global puts access control from a trusted industry leader 

within reach. 
ACW2-XN can be expanded to support up to sixteen doors with additional AW2 Wiegand door modules. 
 

 

Содержание ACW2-XN

Страница 1: ...ost or stolen credentials Use a standard web browser to access the intuitive management portal The web based portal HID Access Manager makes it convenient to provision and revoke smart cards without t...

Страница 2: ...s per Person Max Logs 100 000 events of Doors 2 Doors or 1 APB Door Expandable to 16 doors or 8 APB Doors Note 1 Additional ACW2 XN and or AW2 modules are required 2 See System Architecture Best Pract...

Страница 3: ...ler Module with an uncrossed network cable Suggested Tools Electric drill Drill bits Masonry steel to suite the site wall materials Screwdriver small flat Wire strippers Side cutters Site plan to lay...

Страница 4: ...The two enclosures are linked with an RS 485 cable saving on long multiple reader cable runs Remember that the total door count still cannot exceed the 16 door limit How many AW2 Modules are needed On...

Страница 5: ...hts reserved Installation Guide Page 5 of 26 Web Based Access Control Solution ACW2 XN 16 Reader 8 APB Door Example Note HID Access Manager will only accommodate 16 doors in total Master and Slave Con...

Страница 6: ...ons NOTE that the Slave ACW2 XN Does NOT connect to the network MUST connect via RS 485 to the Master ACW2 XN Is able to continue reading cards and controlling its doors in the event of an RS 485 cabl...

Страница 7: ...as per instructions above 7 Mount the enclosure to the surface 8 Replace the lid and plug the lid cable back in after the system wiring is complete 9 Place the AC and AW2 module labels in the correct...

Страница 8: ...0 150 m 492 ft MOV included in the packaging Specification MOV Rating 25VRMS 500A 77VMax Clamping Where to use the suppled MOVs The MOVs MUST be connected across 12V inductive loads to prevent sparkin...

Страница 9: ...IP switch Position Function 1110 Factory Set DIP Switch Position Wiegand 26 bit 44 bit 40 bit 37 bit and card PIN code Mode Module Data LED Relay 1 Terminals Relay 2 Terminals Wiegand Reader 1 Termina...

Страница 10: ...egand Module are connected across any inductive loads NB The supplied MOVs are only suitable for 12V applications CAUTION Inadequate spark suppression can result in early failure of relay contacts and...

Страница 11: ...ngs while already powered up must be powered down and powered up again This is because the settings are only read by the module during the power up cycle DIP switch Position Function MODE 0000 Slave C...

Страница 12: ...wnload from the More Documentation link included on page 2 Earthing Terminal The Controller and Wiegand Modules are sensitive to Electrostatic Discharges ESD Observe precautions while handling the cir...

Страница 13: ...wire end into its corresponding terminal 5 Releasing the terminal button will clamp the stripped wire end in place 6 Take some time to thoroughly inspect all the wiring and correct any mistakes before...

Страница 14: ...ersion 10 1 1 Android 6 Windows 7 DNS Name function The DNS Name function only works with a PC If you wish to use DNS feature with mobile phones then you need to set the DNS setting within your WLAN r...

Страница 15: ...ress 1 Click Start Control Panel 2 Click the Network and Sharing Centre icon 3 Select Local Area Connection 4 Click the Properties button 5 Double click Internet Protocol Version 4 TCP IPv4 6 Set the...

Страница 16: ...ss Manager will open on the Live Screen Required Settings Using the menu driven interface paths shown on the next page complete these steps 1 Set the date and time 2 Update the master password 3 Add C...

Страница 17: ...ettings Date and Time Security Changing the password Special Days Add public holidays etc Language Change language preference Preferencia cambiar idioma Advanced options o Access Groups o UDP output D...

Страница 18: ...em wiring is complete and tested on the built in power supply Battery Specification Type Lead Gel Voltage 12V Capacity 7 Ah Physical Dimensions 65 mm x 101 mm x 151 mm 2 56 x 3 98 x 5 95 or smaller Ba...

Страница 19: ...nductive loads see page 8 Inter Module Communications Connector Purpose 10 way connectors Female on the left male on the right Power and data lines to other modules Wiegand Reader Port Connector Reade...

Страница 20: ...as intruders cannot just walk in when power is lost Which lock to use Mag locks are inherently Fail Safe as they require power to lock Strike locks are available in Fail Safe as well as Fail Secure v...

Страница 21: ...ans that access control in the remote area will continue to function normally in the event of a break in the RS 485 cable The cable break event will logged on the ACW2 XN Master When the RS 485 cable...

Страница 22: ...regoing license grant and terms and conditions of this EULA Licensee may make the Software and Documentation available to a third party to operate the Software on behalf of Licensee provided that Lice...

Страница 23: ...on or in any copy made of the Software or Documentation 6 Warranty and Disclaimers 6 1 Limited Warranty HID warrants that for a period of ninety 90 days from the date the Software is delivered to Lice...

Страница 24: ...b obtain for Licensee a license to continue using the Software or c if non infringing product or a license to use the Software cannot be obtained upon commercially reasonable terms as determined solel...

Страница 25: ...ase order or other Licensee document usage or custom shall be deemed to amend or modify this EULA If any of these provisions are held to be unenforceable in any jurisdiction for any reason such provis...

Страница 26: ...Page 26 of 26 Installation Guide 2018 HID Global Corporation All rights reserved Web Based Access Control Solution ACW2 XN 13 Notes...

Отзывы: