Mounting Fascia
Mounting Fan Unit
1. The ventilation should be ducted through the roof space, ducting to an external soffit under the eaves or
grille in the slope of your roof.
Ducting can only run between joists, not across them.
2. Mark the position of the fascia with a pencil in a suitable posistion on the ceiling, making sure that it is
between joists.
3. Drill a 9mm hole through the ceiling along the edge of the pencil line. Now cut out the hole with a pad
saw.
4. Hold the fascia against the ceiling and mark the posistion of the fixing holes, fix the unit in place using
suitable fixings- (not supplied)
5. Attach the flexible ducting with the metal hose clamps.
Ensure the ducting has a smooth flow towards the
motor body. Follow a simular procedure for the outside wall grille.
Extra ducting may be used to extend
the distance to the external grille but the performance will be reduced.
Install the Turbo Inline fan within the loft or ceiling space,
DO NOT COVER
the motor or LED driver with loft
insulation. The fan is only suitable for
horizontal mounting
on a wall or floor. Follow the visual aids below to
mount the Fan unit.
Do not run the ducting over the joists, this will cause a build of condensation and reduce the extraction rate.
Ensure the ducting is run between joists to create smooth airflow.
min 1m
fig. A
horizontal on a wall
fig. B
horizontal on a floor
Do not
mount vertically