background image

Quality Bathroom Products

Wall Mounted Ventilation

Fixing Instructions

Thank you for purchasing this HiB product.  
Please read through these instructions carefully 
and refer back to them during installation to 
ensure that your product is fi tted safely and that it 
retains its high quality fi nish.

Please retain this leafl et for future reference.

Electrical Safety Information

HiB recommends that all electrical bathroom 
products should only be fi tted by a suitably 
qualifi ed, Part P registered electrician in 
accordance with current IEE reguations.
Ensure mains power supply is switched off before 
starting installation.
Before drilling, ensure there are no hidden cables 
or pipes in the wall.

Technical Information

Power input: 

220-240 V, 50 Hz

Maximum ventilation volume:

 88 m

3

/hr ( ±5%)

Power consumption: 

14W

Dimensions: 

W152 x H152 x D126mm

Breeze, discreet wall fan

Art nos. 31100, 31200

Breeze, discreet wall fan

Art nos. 31300, 31400

©HiB Copyright:

 No part of this document may be reprinted or 

duplicated without HiB consent. All sizes and measurements are 

approximate, but we do try and make sure they are as accurate as 

possible.  In the interest of continuous product development, HiB 

reserves the right to alter specifi cations as necessary. E & OE.

zone

1

zone

2

zone

2

zone

2

zone

2

zone

2

outside

zone

60cm

60cm

60cm

60cm

75cm

75cm

75cm

75cm

60cm

radius

225cm

225cm

zone

1

zone

2

Figure 1

HiB Ltd, Castle House,
21-23 Station Road, 
New Barnet, Herts,
EN5 1PH

t. 020 8441 0352
f. 020 8441 0219
e. [email protected]
w. www.hib.co.uk

All installations must comply with guidelines which are based on a zonal concept. 
The diagram above illustrates this concept and must be followed to ensure the safe 
installation of bathroom ventilation. These regulations apply to domestic installations 
only.  Installations must be made in accordance with the current IEE wiring regulations 
and relevant building regulations.  HiB recommends that all electrical bathroom products 
should only be fi tted by a suitably qualifi ed, Part P registered electrician. This product is 
suitable for installation in Outside Zones.

Отзывы: