NOTE
CTC cannot be activated with the boom system folded.
Manually control the 1st boom in CTC mode
In CTC mode, SPACE calculates the optimum angle for the boom system to optimize the lifting
capacity. If the optimum position cannot be used because of obstacle, the operator can manually
position the first boom
1. Make sure CTC is selected in the menu.
2. Push button
on the controller to disconnect the 1st boom from CTC mode.
3. Use levers to manually control the 1st boom. The crane tip will not move during this time.
• XSDrive
• CombiDrive
Now, when operating X and Y direction, only 2nd boom and extension are operated.
Push button
again to deactivate.
NOTE
The crane tip will not move until the 1st boom reaches its optimum position.
6.1.5. APO Automatic power off
APO is a function which automatically switches off the power to the control system. It consists of:
1. Timeout controlled power off. (30 minutes by default).
2. Parking brake controlled power off.
Through the vehicle’s parking brake, APO offers a safety function which ensures that the
control system is off when the vehicle is moving. When parking brake is released, the control
system receives a signal and shuts OFF.
For emergency operation
During 5 seconds, it is possible to activate the control system by pushing the ON/OFF button
on the user panel.
6.1.6. ADO Automatic dump function
If a lever is not moved for 3 seconds, this function diverts the oil to the tank, thereby preventing the
oil from overheating. The next lever movement stops the dumping and it functions as normal.
6.1.7. ASC Automatic Speed Control
The ASC function automatically provides the extra power by reducing the speed smoothly, when
working close to the rated capacity. When the load decreases, normal speed is restored.
During operation
72