Hi-Flame Olymberyl Gabriel OL357i-B Скачать руководство пользователя страница 1

Model OL357i-B Olymberyl Gabriel Inset Boiler

 

Multi Fuel and Wood Burning Inset Boiler Stove

Instruction Manual

-

-

Published July 2013

Please note

 This appliance has been independently 

CE tested and approved for the burning of wood 
and multi fuels and must, at all times, be used in 
accordance with these instructions to ensure safe  
and efficient operation.

You will need to refer to the serial number of your 
stove should you ever need to make a claim under the 
Olymberyl® Warranty

You will find the serial number, 

beginning with OL, on the CE plate underneath the 
removable ash lip (see page 3) at the front of the 
stove as well as on the lid of the outer packaging. 
Write the date the stove was delivered to you below 
as this is likely to differ from the purchase date.
Remember to keep your receipt as proof of purchase.

Ref: OL357i-B / UK-NI-ROI / V3.10-07-13

www.hi-flame.com

®

®

Vertical view

L.H.Side view

��

���

���

���

���

���

��

���

���

���

���

®

CE EN13240

CE EN13229

Содержание Olymberyl Gabriel OL357i-B

Страница 1: ...ion You will need to refer to the serial number of your stove should you ever need to make a claim under the Olymberyl Warranty You will find the serial number beginning with OL on the CE plate underneath the removable ash lip see page 3 at the front of the stove as well as on the lid of the outer packaging Write the date the stove was delivered to you below as this is likely to differ from the pur...

Страница 2: ......

Страница 3: ...ore some of the stove photographs and diagrams used which are used for guidance purposes only may differ slightly from your new Gabriel Inset Boiler stove However the principles illustrated here remain the same Hi Flame Fireplace UK Limited INTRODUCTION Thank you for purchasing the Olymberyl Inset Boiler stove We are confident that it will warm your home even on the coldest winter days and provide ...

Страница 4: ...SIONS 4 Vertical view L H Side view Vertical view L H Side view Vertical view L H Side view All sizes in mm Vertical view L H Side view Vertical view L H Side view Vertical view Vertical view L H Side view 265 35 56 ...

Страница 5: ...inal Heat Output To Room 4 8 kW To Water 7 5 kW TOTAL 12 3 kW Efficiency net 80 2 Mean CO Emission at 13 0 52 Mean Flue Gas Temperature 296ºC Flue Gas Mass Flow 7 0 g s MINERAL FUELS Ancit Continuous Burning 2 0 hour refuel period Nominal Heat Output To Room 3 7 kW To Water 8 9 kW TOTAL 12 6 kW Efficiency net 75 8 Mean CO Emission at 13 0 47 Mean Flue Gas Temperature 333ºC Flue Gas Mass Flow 7 6 g s...

Страница 6: ...of the stove when it is in use Check and clean the stove s flue way and the top of the baffle plate regularly to help avoid potential blockages Clean your chimney regularly BOILER STOVE SYSTEMS SPECIFIC SAFETY ISSUES This stove requires a dedicated non closable air vent of the appropriate size for its maximum heat output and this should be located in the same room as the stove An adequate supply of ...

Страница 7: ...y the Government to approve solid fuel domestic heating appliances and the registration of competent installers HETAS registered installers in England and Wales can self certificate their work thus avoiding the need for costly and time consuming Building Notice applications to the local Building Control department They will provide you with a certificate of compliance upon completion of the installa...

Страница 8: ...nd here www smokecontrol defra gov uk Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of Smoke Control Areas and you can contact them for details of Clean Air Act requirements Even if you don t live in a Smoke Control Area it is still the householder s legal responsibility not to cause nuisance smoke Your inset stove therefore shoul...

Страница 9: ...and the access to the flue way to avoid potential soot build up and blockages Once you know how to do this it is a very easy operation See page 10 Flue spigot plate To maximise efficiency and safety the OL357i B Inset Boiler stove has been designed to work best in conjunction with a 150mm 6 flexible flue liner connected to the purpose designed spigot housed on top of the stove To avoid soot build up o...

Страница 10: ...ishes To back of stove 3 Carefully remove from the fire chamber 2 Drop down at angle 1 Push upwards and pull forward such as porous stonework tile grout or carpets as there will inevitably be some sooty debris removed with the baffle When the stove and boiler are cold simply put your hand inside the roof of the fire chamber and push upwards This will release the plate which should then be pulled forw...

Страница 11: ...m and chimney Unpleasant smoky smells both inside and sometimes outside the house In the event of a problem with your stove always check your choice of fuel first Manufactured or finished wood products such as plywood and chipboard must also be strictly avoided because of the high chemical adhesive content used in their production which will also leave harmful potentially corrosive residue inside th...

Страница 12: ...ontrol the different types of combustion air that wood and mineral fuels need Your new stove can burn very well or very poorly depending on how you light the fire how you refuel the fire and of course the type and quality of the fuel that you are burning A log moisture meter is a cost effective investment if you want to maximise the efficiency of your stove and wood fuel Wear protective gloves when l...

Страница 13: ...placed against the boiler sides restrict combustion and can create unwanted cold spots in both the log and the water As the end grain of the wood produces more of the remaining moisture and gases whenever possible point the log ends away from the glass to help keep the glass clean Fuel Load Ideally the logs should be approximately 275mm 11 long A typical fuel load should weigh 2 5 kg 5lb 8oz with ...

Страница 14: ...ckly set Wood burns best if the flames have other wood to play off For example a single dense piece of wood or log will not burn as well as 2 or 3 smaller logs of equivalent mass The more contact the wood has with each other piece the hotter the embers will be 3 or 4 logs tightly packed to each other will burn longer but at a lower temperature than loosely criss crossed logs Approximately 1 5kg to ...

Страница 15: ...g tips 1 Boiler stoves operate at a much lower temperature than non boiler stoves and consequently the potential to create soot or creosote build up in the flue system is also much greater especially when operating the stove in slumber mode during overnight burning We therefore recommend burning your Gabriel Inset Boiler on high output for at least 30 minutes each day to help burn off any potential...

Страница 16: ...the burn rate of the mineral fuel load and therefore the heat into the room To do this ensure the Primary and Secondary Air is fully closed Then simply control the flame pattern and burn rate with the Thermostat Control However you may still need to undertake some subtle adjustments to both the Primary and Secondary Air supply to achieve the correct balance of combustion air for your stove and flue ...

Страница 17: ... building regulations it is also a requirement of your Warranty that the stove is installed by a competent person such as a Hetas or INFO registered installer who will be fully aware of any building and safety regulations which apply to stove installations in your location Inset Boiler Stove Location Checklist The existing constructional hearth the main part of the hearth is suitably constructed a...

Страница 18: ...he edge of the ash lip As a general rule it is best to extend the hearth to at least 75mm 3 beyond the furthest out swing of the stove door if possible to avoid any potential live ash held on the inset door falling on to combustible flooring or floor coverings If the top of the hearth and any combustible floor coverings are level with each other then a retaining fender should be fitted to warn occupan...

Страница 19: ... stoves create flue gases at a much greater temperature than those produced by an open fire or gas appliance it does not necessarily follow that your chimney will function adequately or safely when your new stove is installed The best way to ensure that you have a fully functioning flue system is to fit an approved flexible multi fuel flue liner If you intend to predominantly burn mineral fuels then 904...

Страница 20: ...ler to possess a knowledge and understanding which will be beyond the provisions and intentions of these general installation and operating guidelines The United Kingdom s Solid Fuel Association through their website www solidfuel co uk provides informative downloads on various link up system solutions The most common problem with link up systems is a failure to understand the existing system whic...

Страница 21: ... 21 ...

Страница 22: ...addition the hot water cylinder and heat leak radiator should be positioned as near to vertically above the boiler stove as possible and with sufficient height to encourage the natural flow Any horizontal runs in this pipework should be inclined again to encourage the natural flow High and low limit thermostats A high limit over heat thermostat set at 80ºC should be fitted to the gravity flow pipework ...

Страница 23: ...the stove but also help avoid the potential build up of combustible soot along the sides this is an especially important requirement if you are not using a flue liner Some installations may require you to do this by removing the stove baffle plate and feeding the insulating material through the stove flueway and then manipulating it with your hand so that it completely fills the voids at the sides and...

Страница 24: ...h the stove to the fireplace see below Carefully position the stove within the fireplace opening and mark the two holes on to the fireplace front Remove the stove and carefully drill the holes using the appropriate drill bit and insert the screw plugs Re position the stove and insert and tighten both screws Remember if you are fitting a liner then the liner attached to the spigot should already be dro...

Страница 25: ...6 25 6 Legal Requirements Explain the householder s legal requirement to use an approved fireguard when ever children or the elderly and the infirm are likely to be in the vicinity of the stove If the installation is in a designated Smoke Control Area then also explain the householder s responsibility only to use approved smokeless fuels 7 Instruction Manual Make sure that the customer receives this...

Страница 26: ...w it is extremely important that the radiators are balanced to ensure an efficient distribution of heat as well as an even heat balance from one radiator to the next The idea is to reduce the flow to the hottest radiators so that more hot flow is available to heat the coolest ones The system is balanced when there is a good hot water flow through every central heating radiator To undertake this all of...

Страница 27: ...y or flue itself also needs cleaning Causes Inadequate supply of combustion air Check that any permanent air vent fitted to supply the extra combustion air required for the stove has not been accidentally blocked Remember there should never be an extractor fan in the same room as a stove A simple way of checking whether or not the stove is receiving enough combustion air is to open a window in the s...

Страница 28: ...me blackening of the glass should be considered a trade off In this instance if you re sure that the fuel from the stove they should only ever be specified fitted and subsequently tested by an approved installer Causes Fuel The fuel itself may be of poor quality For example pine and other softwoods used in the building trade will burn much quicker than a good hard wood log such as Oak Causes Faulty ...

Страница 29: ...ikely to be a problem with the system The simplest way to determine this is if possible to check that the top water pipe from the stove is hot and that the lower pipe is cooler If this is the case then this indicates that there is a problem with the system and not the stove Causes Circulation pump or thermostatic valve failure A fault in one of the system s key components could restrict the system...

Страница 30: ...taining to build up as it will become more difficult to remove after each firing When used regularly a proprietary scratch resistant stove glass cleaning gel or spray which can be supplied by your stove dealer applied with a soft cloth should be sufficient to keep the glass in pristine condition Make sure the glass is cold before you apply such cleaners as applying a cold solution to hot glass could ...

Страница 31: ...oprietary heat resistant fire rope glue to secure the rope and glue both ends to ensure a well sealed joint The recommended rope seal diameter is 12mm Air flow through stove The heat from your inset stove comes in the form of radiated heat from the hot castings and convection of hot air This convection is achieved by the stove drawing colder air in through the two side air intake vents at the base d...

Страница 32: ...e free from defective parts materials and workmanship at the time of purchase by the original consumer for a period of 1 year for components parts and labour excluding consumable parts and 5 years for the bodywork casing door and boiler parts and 1 year labour The warranty does not cover parts deemed to be consumables These include paint firebricks fire grates vermiculite panels smoke deflection plat...

Страница 33: ...l parts for wear or damage and replace as necessary Re fit all the internal parts Stove Glass Check the glass for chips or cracks and the glass seal condition and replace if necessary Thoroughly clean the stove glass on both sides Door Seal Check that this makes an air tight seal and replace if necessary Ensure that the new rope joint is also in the middle at the base of the rope seal channel Exter...

Страница 34: ...TES AND SETTINGS For future reference include a basic drawing of the system and notes on the circulation pump and system thermostat settings etc as well as their location and the location of the system drain point ...

Страница 35: ......

Страница 36: ...Cheshire CW4 8AF United Kingdom Olymberyl Multi Fuel Stoves 2010 2011 2012 and 2014 All rights reserved Booklet contents may not be copied in whole or in part without the prior written permission of the copyright holder Olymberyl and Gabriel are the registered trading name of Hi Flame Fireplace UK Limited CE EN13240 CE EN13229 ...

Отзывы: