background image

 

 

 
 

Installation and Operation Instructions  
for

 USA only

 

Model: HF-717UA  

Cast Iron Freestanding Stove 

EPA Approved

 

 

 

 

 

 

 

 

KINDLY SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

 

 

Содержание HF-717UA

Страница 1: ...Installation and Operation Instructions for USA only Model HF 717UA Cast Iron Freestanding Stove EPA Approved KINDLY SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...ROPERTY DAMAGE BODILY INJURY OR EVEN DEATH FAILURE TO READ AND FOLLOW THESE INSTRUCTIONS BEFORE YOU PROCEED MAY RESULT IN DAMAGE VOIDING YOUR WARRANTY DO NOT INSTALL IN A MOBILE HOME DO NOT USE CHEMIC...

Страница 3: ...ovision 5 Installation 5 Floor Protection 6 Installation Clearances 7 Well Sealed Flue System 8 Chimney Connector 8 Chimney 9 Factory Built Chimney 10 Masonry Chimney 11 Masonry Fireplace 12 Combustib...

Страница 4: ...3 Sample of Label...

Страница 5: ...essure conditions may occur such as through the use of extraction fans unless an adequate air supply into the room is ensured as this may draw air through the stove and cause products of combustion to...

Страница 6: ...combustible materials in proximity to the stove Adequate air provision It is essential for the safe and efficient use of your stove that you provide an adequate air supply when lighting a fire especia...

Страница 7: ...please contact your dealer immediately The floor protection If the stove is to be installed on a combustible floor it must be placed on a non combustible hearth pad In the USA the floor protector must...

Страница 8: ...ch fire The clearance from the top of the unit to the ceiling is 75 190 5 cm All other clearances are found in the table below A combustible surface is anything that can burn i e sheet rock wall paper...

Страница 9: ...ny other combustible materials of the house It is also essential that the flue system is kept clean and seals are maintained to ensure the draft is not lost The open end of the flue system must be abo...

Страница 10: ...of the chimney connectors must be accessible for cleaning Where passage through a wall or partition of combustible construction is desired the installation must conform to National Fire Protection As...

Страница 11: ...ame manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to...

Страница 12: ...ociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed an...

Страница 13: ...There are listed kits available to connect a stove to a masonry fireplace The kit is an adapter that is installed at the location of the fireplace damper The existing damper may have to be removed to...

Страница 14: ...13 Combustible Wall Chimney Connector Pass Throughs...

Страница 15: ...put the stove into full service Allow the stove to fully cool between each of these fires There may be some smell and a small amount of smoke from the stove during the initial operations This is perf...

Страница 16: ...combustible container as there may be hot ash in the center of the pile You should always wear protective gloves when removing ash from the stove This stove is not designed to operate with the door op...

Страница 17: ...use a stove that is in any way damaged or has a damaged flue 1 Check your flue system for build up of soot or creosote and for signs of damage to joints To check flue outlet remove top of baffle by li...

Страница 18: ...the glass panel and gasket 4 Using a wire brush remove all remaining debris from the glass area 5 Apply a small bead of gasket stove cement to the new gasket Do not overlap the ends of the gasket rop...

Страница 19: ...18 HF 717UA Part List...

Страница 20: ...plate 33 Brick retainer 11 Front side fire brick 2 34 Glass clips 4 12 Left side fire brick 35 Wood handle 13 Back fire brick 36 Countersunk head screw M6 x 70 14 Rear heat shield 37 Stainless steel h...

Страница 21: ...y wood Smoke in room If the stove is properly installed it should not emit any smoke into your room Check to see if your chimney is blocked or obstructed and that you are not getting a down draft caus...

Страница 22: ...etected by sparks coming from the top of the chimney a roaring sound coming from the area of the stove or chimney or vibration in the stove or chimney In the event of a chimney fire close the air cont...

Страница 23: ...ny stove or fireplace insert or part thereof found to be defective DESCRIPTION Warranty Defined Parts Labor Cast Iron Parts 7 Years 1 Year Firebox welding only 5 Years 1 Year Handle Assembly 5 Years N...

Страница 24: ...by over firing which causes any part of the appliance to glow red as defined in the operation manual Over firing can be identified by warped plates rust colored cast iron paint pigment that has turne...

Отзывы: