Please note

 This appliance has been independently 

CE tested in the United kingdom and approved for 
the burning of wood and mineral fuels and must, 
at all times, be used in accordance with these 
instructions to ensure safe and efficient operation.

You will need to refer to the serial number of your 
stove should you ever need to make a claim under 
the Alpha Warranty

You will find the serial number, 

beginning with AL, on the CE plate at the rear of the 
stove as well as on the lid of the outer packaging. 
Write the date the stove was delivered to you below 
as this is likely to differ from the purchase date.
Remember to keep your receipt as proof of purchase.

Ref: AL910-B / UK-NI-ROI / V2.12-07-13

A

LPHA

Collection

The

Alpha III Boiler Handbook.indd   1

16/7/13   10:58:45

Содержание AL910-B Alpha III

Страница 1: ...ensure safe and ef cient operation You will need to refer to the serial number of your stove should you ever need to make a claim under the Alpha Warranty You will nd the serial number beginning with...

Страница 2: ...remain the same Hi Flame Fireplace UK Limited INTRODUCTION Thank you for purchasing the Alpha III Boiler stove We are con dent that it will warm your home even on the coldest winter days and provide...

Страница 3: ...3 GENERAL DIMENSIONS All sizes in mm Alpha III Boiler Handbook indd 3 16 7 13 10 58 50...

Страница 4: ...To Space 5 7 kW To Water 9 4 kW TOTAL 15 1 kW Ef ciency net 74 9 Mean CO Emission at 13 0 43 Mean Flue Gas Temperature 346 C Flue Gas Mass Flow 10 6 g s Mineral Fuels Ancit Continuous Burning 2 0 hou...

Страница 5: ...n use Check and clean the stove s ue way and the top of the baf e plate regularly to help avoid potential blockages Clean your chimney regularly BOILER STOVE SYSTEMS SPECIFIC SAFETY ISSUES This stove...

Страница 6: ...ernment to approve solid fuel domestic heating appliances and the registration of competent installers HETAS registered installers in England and Wales can self certi cate their work thus avoiding the...

Страница 7: ...e for implementing the Clean Air Act 1993 including designation and supervision of Smoke Control Areas and you can contact them for details of Clean Air Act requirements Even if you don t live in a Sm...

Страница 8: ...ot build up and blockages Once you know how to do this it is a very easy operation See below Flue Outlet The AL910 B stove has a 150mm 6 ue outlet on the top of the stove there is no rear ue outlet op...

Страница 9: ...boiler as well as the ue way First remove the stove lid by undoing the two bolts towards the rear of the ue pipe Use the correct sized Phillips crosshead screwdriver The heavy cast iron lid can then...

Страница 10: ...and sometimes outside the house In the event of a problem with your stove always check your choice of fuel rst Manufactured or nished wood products such as plywood and chipboard must also be strictly...

Страница 11: ...od and mineral fuels need Your new stove can burn very well or very poorly depending on how you light the re how you refuel the re and of course the type and quality of the fuel that you are burning A...

Страница 12: ...1 between both ends of the logs and the boiler sides Log ends placed against the boiler sides restrict combustion and can create unwanted cold spots in both the log and the water As the end grain of t...

Страница 13: ...f the ames have other wood to play off For example a single dense piece of wood or log will not burn as well as 2 or 3 smaller logs of equivalent mass The more contact the wood has with each other pie...

Страница 14: ...at a much lower temperature than non boiler stoves and consequently the potential to create soot or creosote build up in the ue system is also much greater especially when operating the stove in slum...

Страница 15: ...To do this ensure the Primary and Secondary Air is fully closed Then simply control the ame pattern and burn rate with the Thermostat Control However you may still need to undertake some subtle adjust...

Страница 16: ...lso a requirement of your Warranty that the stove is installed by a competent person such as a Hetas or INFO registered installer who will be fully aware of any building and safety regulations which a...

Страница 17: ...stove when loaded and boiler with water add ap prox 15kg along with any attached exible ue liner which may bear down on the stove This hearth must conform to local building regulations which may vary...

Страница 18: ...himney could leak smoke fumes and potentially dangerous invisible carbon monoxide into other parts of the building Condensation or creosote tar often associated with burning wood could eventually seep...

Страница 19: ...should be used for general guidance purposes only and is included here to demonstrate basic system principles Combined with the at a glance list below this should provide you with a basic understandi...

Страница 20: ...20 Alpha III Boiler Handbook indd 20 16 7 13 10 59 12...

Страница 21: ...safety precaution will ensure that the gravity circuit does not overheat A low limit thermostat set at 45 C should be tted to the gravity return pipework and connected to the circulating pump This sho...

Страница 22: ...ts Explain the householder s legal requirement to use an approved reguard whenever children or the elderly and the in rm are likely to be in the vicinity of the stove If the installation is in a desig...

Страница 23: ...nt that the radiators are balanced to ensure an ef cient distribution of heat as well as an even heat balance from one radiator to the next The idea is to reduce the ow to the hottest radiators so tha...

Страница 24: ...himney or ue itself also needs cleaning Causes Inadequate supply of combustion air Check that any permanent air vent tted to supply the extra combustion air required for the stove has not been acciden...

Страница 25: ...s not get hot enough and some blackening of the glass should be considered a because draught stabilisers limit the exit of ue gases from the stove they should only ever be speci ed tted and subsequent...

Страница 26: ...ikely to be a problem with the system The simplest way to determine this is if possible to check that the top water pipe from the stove is hot and that the lower pipe is cooler If this is the case the...

Страница 27: ...as it will become more dif cult to remove after each ring When used regularly a proprietary scratch resistant stove glass cleaning gel or spray which can be supplied by your stove dealer applied with...

Страница 28: ...middle horizontal rope that seals the ash pan chamber from the re chamber to maintain a good Primary Air ow The recommended rope seal diameter is 12mm Air Supply Controls There are three air supply co...

Страница 29: ...ear labour The warranty does not cover parts deemed to be consumables These include paint rebricks re grates vermiculite panels smoke de ection plates baf e plates gaskets rope seals and glass Alpha w...

Страница 30: ...mage and replace as necessary Re t internal parts and ueway access lid Stove Glass Check the glass for chips or cracks and the glass seal condition and replace if necessary Thoroughly clean the stove...

Страница 31: ...e reference include a basic drawing of the system and notes on the circulation pump and system thermostat settings etc as well as their location and the location of the system drain point Alpha III Bo...

Страница 32: ...8AF United Kingdom Alpha Multi Fuel Stoves 2010 2011 2012 and 2013 All rights reserved Booklet contents may not be copied in whole or in part without the prior written permission of the copyright hol...