FRU Replacement Guide
7 Storage Enclosure Basic Field Replaceable Units
93
d) Wait for the
Status
field to change to
DONE
.
Warning:
Even if all LEDs are off, you must still wait until the CMC shows
DONE
in the
Status
field.
All I/O to the Storage Enclosure Basic attached to this Storage Node is now quiesced.
2.
Lift the cord retention bale and unplug the power cord from the failed power supply unit.
Figure 67: Removing the Power Cord
Note:
• Cord retention bale marked in blue.
• If you are removing power supply A, you do not need to remove the miniSAS cables. To remove
power supply B, it is recommended that you remove the miniSAS cables for ease of replacement.
To remove the miniSAS cables, pull the
blue tab
and remove the cable from the port. Repeat for
both miniSAS cables as necessary.
3.
Unlock the failed power supply unit by pulling the
latch handle
out and away from the I/O canister.
Note:
• The power supply unit latch handle should be at 45° when removed.