![Hexagon VERIPOS LD900 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/hexagon/veripos-ld900/veripos-ld900_installation-and-operation-manual_2128203057.webp)
Troubleshooting
LD900 Installation and Oper ations M anual
57
5 Troubleshooting
The LD900 uses a colour LCD screen and navigation panel to provide status information and help with
troubleshooting issues.
CAUTION
Front and rear panels should not be removed
.
Please contact your VERIPOS project manager if
maintenance is required.
Most potential problems that might occur when using this system will relate to signal reception problems or
conf iguration errors. This section will assist in resolving the most commonly encountered system issues.
5.1 Hardware Issues
Hardware f ault finding should be limited to checking that all connectors are secure and checking supply voltage.
Bef ore thorough investigations are undertaken, it is
strongly recommended
to verify coaxial cable
connections, cable integrity and correct antenna siting. For further guidance please see:
•
Antenna and Coaxial Cable Installation Manual
•
GNSS Heading Antenna Installation Guide
(where relevant to installation)
5.2 Power Issues
5.3 Activation Issues
Fault Description
Possible Cause
Solution
Screen blank
Screen brightness setting.
Adjust screen brightness using the buttons
on the lef t-hand side of the LCD display.
External supply fault or external supply
disconnected or switched off.
Check power connection to the unit for
physical, fuse and electrical integrity.
Fault in AC/DC supply.
Disconnect the power supply. Check
voltage to and from the supply. The LD900
AC 110/240 should supply 12-24 VDC to
the LD900.
Hardware Fault
If the PSU voltage is correct, contact
.
Fault Description
Possible Cause
Solution
Grey Corrections
indicator
Unit disabled
Contact
with vessel name,
Red Corrections
indicator
No L-band signal
See section
.