©Hexagon Mining
19
2.
Connect the cigarette plug connector side in the supplied power cable to the vehicle cigarette socket
3.
Route and secure all cables and wiring to meet Hexagon Mining requirements and ensure that there is
no rubbing, which can cause premature failure.
4.
Connect the other side of the power cable in the OAS-LV unit. Make sure the cable connector will lock in
the OAS-LV Power connector.
3.2.1.2
Regular installation
1.
Connect the supplied power cable to a reliable power source, for example, the vehicle’s main power
system.
2.
Connect the red wire to a 9-32-volt positive, 3A fused power source, capable of delivering a constant 5A.
3.
Connect the black wire to the vehicle’s earth.
4.
Connect the blue wire to a 9-32-volt positive, 5A fused source that is active (positive voltage) when the
vehicle’s ignition key is turned to the “ON” position.
5.
Route and secure all cables and wiring to meet Hexagon Mining requirements and ensure that there is
no rubbing, which can cause premature failure.
6.
Connect the other side of the power cable in the OAS-LV unit. Make sure the cable connector will lock in
the OAS-LV Power connector.
3.3
Antenna Installation
3.3.1 GNSS Antenna Application
To ensure correct antenna application, refer to the Antenna Application table.
WARNING
Only antenna listed in the Antenna Application table are permitted to be used. If higher
powered antennas are used, injury to personnel may occur.
WARNING
The Wi-Fi antennas must be mounted more than 30cm away from the operator.
CAUTION
Only antenna cables provided with the OAS-LV module equipment for installation, and as
identified in the specific OAS-LV module installation diagrams are to be used in OAS-LV
module antenna installations to ensure optimal performance and meet regulatory
requirements.
GNSS Antenna Application
Module
Required Antenna: Hexagon Mining Part Number
OAS-LV
GNSS: 913422