![Hewlett Packard Enterprise StoreEver 8096 Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/hewlett-packard-enterprise/storeever-8096/storeever-8096_users-and-service-manual_2128096145.webp)
Troubleshooting information and procedures
CAUTION:
Shipping Lock:
The shipping lock must be removed for the robotics to operate properly on the
MSL2024 and MSL4048. The library displays a robot move error if the shipping lock is not removed (see
on page 33).
The library displays errors
Symptom
The library displays library errors and the library edges are not properly supported.
Cause
CAUTION:
This library is designed to operate when installed in a rack using the included rack rails. Operating the
library without installing it in the rails, such as on a table or rack shelf, could result in library errors.
Placing any weight on top of the library might also cause errors.
Fibre Channel connection problems
The MSL4048 library will not operate with a full-height tape drive installed in the middle two half-height drive
bays. Verify that the full-height tape drive is installed in a supported position. A full-height drive can only be
installed in either the upper or lower two half-height drive bays.
Use the Status screen to check the link connection for your tape drive.
If the screen shows Logged Out:
• Check that the Fibre speed is set to Automatic (on the RMI) or Auto Detect (on the OCP), or that the
correct fibre speed is selected. If you are unsure of the speed of the HBA or switch that the library is
connected to, try Automatic (on the RMI) or Auto Detect (on the OCP).
• Check that the correct port type, fabric or loop, is selected. Loop requires additional configuration. If you
are unsure of the correct port type, try Automatic (on the RMI) or Auto Detect (on the OCP).
If the screen shows No Link, the Speed Status is – and the Link LED on the back of the drive is off:
• The speed is probably set incorrectly. Try setting the speed to Automatic (on the RMI interface) or Auto
Detect (on the OCP).
• If there are still issues, change the port type to Auto Detect.
If the screen shows No Light:
• The cable is not plugged in correctly. Check that it is connected correctly to Port A of the tape drive.
• The cable is damaged. FC cables are delicate. If the cable has been bent or twisted sharply, it might be
broken and must be replaced.