Deployment
Installing Synergy SAS storage solution components
Minimum requirements for VSAN configurations include the following:
• Smart Array driver—1.0.0.1060
• VMWare kernel— 6.5u1
HPE Synergy 12Gb SAS Connection Module installation guidelines
• The HPE Synergy 12Gb SAS Connection Module can be hot-installed in an operational frame.
• The HPE Synergy 12Gb SAS Connection Module does not have a power on/off button.
• Power is automatically applied or removed when the module is installed or removed from the frame. Power can also be
applied or removed through HPE OneView.
• For single-domain Fabric one deployments, the connection module must be installed in the following configurations:
◦
If an HPE Synergy D3940 Storage Module is installed in compute bays 1-6, the connection module must be installed in
interconnect module bay 1.
◦
If an HPE Synergy D3940 Storage Module is installed in compute bays 7-12, the connection module must be installed
in interconnect module bay 4.
• For dual-domain Fabric one deployments, the HPE Synergy 12Gb SAS Connection Module must be installed in interconnect
module bays 1 and 4.
Installing an HPE Synergy 12Gb SAS Connection Module
Procedure
1. Open the release lever.
2. Install the HPE Synergy 12Gb SAS Connection Module, and then close the release lever.
Deployment
23
Содержание Smart Array P416ie-m SR Gen10 Controller
Страница 33: ...Deployment 33 ...
Страница 36: ...9 Click Create to create the enclosure group or click Create to create multiple enclosure groups 36 Deployment ...
Страница 46: ...46 Deployment ...
Страница 49: ...Deployment 49 ...
Страница 52: ...52 Deployment ...
Страница 72: ...voltage regulator module VSA virtual storage appliance 72 Acronyms and abbreviations ...